Hp_Sensorcollection; Hp_Memberofsensorcollection - HP Integrity rx7620 Datasheet

Hp insight management wbem providers on integrity servers data sheet
Hide thumbs Also See for Integrity rx7620:
Table of Contents

Advertisement

HP_SensorCollection

6-3-2
HP_SensorCollection is used to model temperature sensor collections on Integrity servers. The
Windows implementation class is HP_WinSensorCollection. There is one instance of this class on
systems modeling sensors.
Table 6-3
Class: HP_SensorCollection
Property name
CIM_ManagedElement
Caption
Description
ElementName
CIM_SystemSpecificCollection
InstanceID
HP_GroupSystemSpecificCollection
GroupOperationalStatus[0]
GroupStatusDescriptions[0]

HP_MemberOfSensorCollection

6-3-3
HP_MemberOfSensorCollection is used to represent an association between HP_NumericSensor and
HP_SensorCollection. The Windows implementation class is HP_WinMemberOfSensorCollection.
Property implementation
Temperature Sensor Collection
This is a collection of temperature sensors.
GroupStatusDescription., where
GroupStatusDescription represents the value of the
GroupStatusDescriptions[0] property
Temperature Sensor Collection
Unique identifier for this sensor collection instance
The most severe sensor group operational status:
2 (OK)—if temperatures reported by the sensors
are within normal operating range;
2 (OK)—if temperatures reported by the sensors
have exceeded its non-critical threshold and has set
fans to full speed;
6 (Error)—if temperatures reported by the sensors
have exceeded its non-critical threshold and the
system is gracefully shutting down
Temperatures reported by the sensors are operating
within normal operating range—if temperatures
reported by the sensors are within normal
operating range;
Temperatures reported by the sensors have
exceeded its non-critical threshold and the fans
have been set to full speed—if temperatures
reported by the sensors have exceeded its threshold
and has set fans to full speed;
Temperatures reported by the sensors have
exceeded its threshold and the system is gracefully
shutting down—if temperatures reported by the
sensors have exceeded its threshold and the system
is gracefully shutting down
5BSystem Temperature Sensor 62

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Integrity rx8620Integrity superdome sx1000

Table of Contents