Verifying The Fan Module - Cisco AJ732A - MDS 9134 Fabric Switch Installation Manual

Cisco mds 9100 series hardware installation guide (ol-17951-02, february 2009)
Hide thumbs Also See for AJ732A - Cisco MDS 9134 Fabric Switch:
Table of Contents

Advertisement

Removing and Installing Components
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m

Verifying the Fan Module

To verify that the new fan module is installed correctly, follow these steps:
Listen for the fans; you should immediately hear them operating. If you do not hear them, ensure that
Step 1
the fan module is inserted completely in the switch and the faceplate is flush with the switch back panel.
Verify that the Fan module LED is green. If the LED is orange, then one fan has failed in this fan module;
Step 2
if the LED is red, then both fans have failed in this fan module.
Contact your customer service representative for assistance if, after several attempts, the fans do not
Step 3
operate or you experience trouble with the installation.
Note
Note
If you purchased this product through a Cisco reseller, contact the reseller directly for technical support.
If you purchased this product directly from Cisco, contact Cisco Technical Support at this URL:
http://www.cisco.com/warp/public/687/Directory/DirTAC.shtm
Cisco MDS 9100 Series Hardware Installation Guide
2-34
Verify that the transceiver and cable type both have LC connectors and are the required type for
longwave or shortwave transmission and the required distances. The transceiver label generally
lists the model and wavelength.
Chapter 2
Installing the Cisco MDS 9100 Series
OL-17951-02

Advertisement

Table of Contents
loading

Table of Contents