Understanding SNMP Basics
Once loaded, the MAX-ACCESS provides access levels between the agent and management station.
The access levels are as follows:

Understanding SNMP Traps

An unsolicited message that comes to the management station from the SNMP agent on the
device is called a trap. Brocade switches send traps out on UDP port 162 and to any configured
port. In order to receive traps, the management station IP address and severity level must be
configured on the switch. Up to six trap recipients can be configured using Web Tools or the
snmpConfig command. You can define a different message severity level for each recipient so that
some recipients receive all trap messages and others receive only the most critical.
There are two main MIB trap choices:
There is some overlap in the functionality of these MIBs. If you enable both SW-MIB and FA-MIB
traps, you could receive duplicate messages for the switch events that trigger the trap.
You can also use these additional MIBs and their associated traps: HA-MIB; FICON-MIB; and
SW-EXTTRA. You can use the snmpConfig command to disable the FA-MIB, HA-MIB, FICON-MIB, and
SW_EXTTRA; but neither the SW-MIB or the FE-MIB can be disabled.
An event trap (swEventTrap, connUnitEventTrap, or swFabricWatchTrap) is basically an error
message (errShow output) that is SNMP-formatted and delivered.
FA Traps
Consider enabling the FA traps if you want to use SNMP to monitor multiple connectivity units,
including Brocade switches.
The switchStatusPolicySet command determines the FA-TRAP switch status-related outputs:
4
Brocade supports FE_RCF2837.mib under the MIB-II branch in Fabric OS v6.2.0, v6.1.0,
v6.0.0, v4.x, v3.2.0, and v3.1.x and the experimental version, FE_EXP.mib, in Fabric OS v2.6.x
and 3.0.x. This latest version of the FE MIB references the FRAMEWORK.MIB and, based on
the MIB browser, it is necessary to load this MIB before the FE.MIB. Refer to
MIBs"
on page 6 for more information.
not-accessible
You cannot read or write to this variable.
read-create
Specifies a tabular object that can be read, modified, or created as a new row in a table.
read-only - Public
You can only monitor information.
read-write - Private
You can read or modify this variable.
FibreAlliance MIB trap - Associated with the Fibre Alliance MIB (FA-MIB), this MIB manages SAN
switches and devices from any company that complies with Fibre Alliance specifications.
Brocade-specific MIB trap - Associated with the Brocade-specific Brocade MIB (SW-MIB),
manages Brocade switches only.
connUnitStatusChange
connUnitSensorStatusChange