Fibre Channel Port Group - Brocade Communications Systems A7533A - Brocade 4Gb SAN Switch Base Reference Manual

Brocade fabric os mib reference guide v6.2.0 (53-1001156-01, april 2009)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

5
swAgtTrapSeverityLevel 1.3.6.1.4.1.1588.2.1.1.1.4.11.1.4
swAgtTrapSeverityLevel 1.3.6.1.4.1.1588.2.1.1.1.4.11.1.4
This is the trap severity level associated with
trap severity level, is in conjunction with the event's severity level. When an event occurs, and if its
severity level is at or below the set value, the SNMP trap is sent to configure trap recipients. The
severity level is limited to particular events. If a new value is set successfully, it takes effect
immediately.
This object obsoletes

Fibre Channel Port Group

This group contains information about the physical state, operational status, performance, and
error statistics of each Fibre Channel port on the switch. A Fibre Channel port is one which
supports the Fibre Channel protocol, such as F_Port, E_Port, U_Port, or FL_Port.
598
swAgtTrapRcp
swEventTrapLevel
1.3.6.1.4.1.1588.2.1.1.1.8.1.
1.3.6.1.4.1.1588.2.1.1.1.4.11.1.3. The
Fabric OS MIB Reference
53-1001156-01

Advertisement

Table of Contents
loading

Table of Contents