If you have other options to install or remove, do so now. Otherwise, go to
"Completing the installation" on page 85.

Installing a hot-swap ac power supply

The following notes describe the type of ac power supply that the server supports
and other information that you must consider when you install a power supply:
v The server comes with one 675-watt hot-swap 12-volt output power supply that
v Power supply 1 is the default/primary power supply. If power supply 1 fails, you
v You can order an optional power supply for redundancy.
v These power supplies are designed for parallel operation. In the event of a
v For instructions on how to install a hot-swap dc power supply, refer to the
Statement 5:
CAUTION:
The power control button on the device and the power switch on the power
supply do not turn off the electrical current supplied to the device. The device
also might have more than one power cord. To remove all electrical current
from the device, ensure that all power cords are disconnected from the power
source.
Statement 8
78
IBM System x3550 M2 Types 4198 and 7946: Installation and User's Guide
connects to power supply bay 1. The input voltage is 110 V ac or 220 V ac
auto-sensing.
must replace the power supply immediately.
power-supply failure, the redundant power supply continues to power the system.
The server supports a maximum of two power supplies.
documentation that comes with the dc power supply.