Features and specifications

The following information is a summary of the features and specifications of the
server. Depending on the model, some features might not be available, or some
specifications might not apply.
Table 1. Features and specifications
Microprocessor:
v Supports up to two Intel Xeon
multi-core microprocessors (one
installed)
v Level-3 cache
v QuickPath Interconnect (QPI) links
speed up to 6.4 GT per second
Note:
v Use the Setup utility program to
determine the type and speed of the
microprocessors.
v For a list of supported microprocessors,
see http://www.ibm.com/servers/eserver/
serverproven/compat/us/.
Memory:
v Minimum: 1 GB
v Maximum: 128 GB
v Type: PC3-10600R-999 (single-rank or
dual-rank), 800, 1067, and 1333 MHz,
ECC, DDR3 registered SDRAM DIMMs
only
v Slots: 16 dual inline
v Supports 1 GB, 2 GB, 4 GB, and 8 GB
DIMMs
SATA optical drives:
v CD-RW/DVD-ROM combo (optional)
v DVD-ROM (optional)
v Multi-burner (optional)
Hot-swap fans:
The server comes standard with six
dual-motor hot-swap fans.
6
IBM System x3550 M2 Types 4198 and 7946: Installation and User's Guide
Hard disk drive expansion bays
(depending on the model):
v Six 2.5-inch hot-swap SAS or
hot-swap SATA hard disk drive bays
v Four 2.5-inch simple-swap, solid state
SATA hard disk drive bays
PCI expansion slots:
Supports two PCI riser slots:
v Slot 1 supports low-profile cards (PCI
Express Gen2 x16 or PCI-X 1.0a
64-bit/133 MHz ).
v Slot 2 supports half-length, full-height
cards (PCI Express Gen2 x16 or
PCI-X 1.0a 64-bit/133 MHz).
Video controller (integrated into IMM):
v Matrox G200eV (two analog ports -
one front and one rear that can be
connected at the same time)
Note: The maximum video resolution
is 1600 x 1200 at 75 Hz.
– SVGA compatible video controller
– DDR2 250 MHz SDRAM video
memory controller
Avocent Digital Video Compression
– 16 MB of video memory (not
expandable)
Power supply: Maximum of two hot-swap
power supplies for redundancy support
v 675-watt ac (110 or 220 V ac
auto-sensing)
v 675-watt dc (-48 V or -60 V dc)
Environment:
v Air temperature:
– Server on: 10°C to 35°C (50°F to
95°F); altitude: 0 to 914.4 m (3000 ft),
decrease system temperature by
1.0°C for every 1000-foot increase in
altitude
– Server off: 5°C to 45°C (41°F to
113°F); maximum altitude: 3048 m
(10000 ft)
– Shipment: -40°C to 60°C
(-40°F to 140°F); maximum altitude:
3048 m (10000 ft)
v Humidity:
– Server on: 8% to 80%
– Server off: 8% to 80%
v Particulate contamination:
Attention:
Airborne particulates and
reactive gases acting alone or in
combination with other environmental
factors such as humidity or temperature
might pose a risk to the server. For
information about the limits for
particulates and gases, see "Particulate
contamination" on page 113.
Heat output:
Approximate heat output:
v Minimum configuration: 662 Btu per hour
(194 watts)
v Maximum configuration: 2302 Btu per
hour (675 watts)

Hide quick links: