HP A7340A - Surestore FC 1Gb/2Gb Switch 16B User Manual page 259

Hp storageworks web tools v3.1.x/4.1.x user guide (aa-rs25c-te, june 2003)
Hide thumbs Also See for A7340A - Surestore FC 1Gb/2Gb Switch 16B:
Table of Contents

Advertisement

Table 64: Port Information Window SFP Tab Field Descriptions (Continued)
Speed
Media
Distance
Encoding
Baud Rate
BR Max
BR Min
Options
Length 9u
Length 50u
Web Tools Version 3.1.x/4.1.x User Guide
Field
Indicates the speed of the SFP in 100, 200, or 400 MB/sec.
Indicates transmission mode, which can be one of the
following:
SM - single mode
M5 - multi-mode, 50u
M6 - multi-mode, 62.5u
TV - video coax
MI - miniature coax
TP - twisted pair coax
TW - twin axial pair
Indicates the length of the Fibre Channel link, which can be
one of the following
long distance
intermediate distance
short distance
Indicates the serial coding mechanism, which can be one of
the following:
8B10B
4B5B
NRZ
Indicates the nominal baud rate in units of 100 Megabaud.
Indicates the upper limit at which the SFP meets its
specifications (in units of one percent above nominal baud
rate).
Indicates the lower limit at which the SFP meets its
specifications (in units of one percent above nominal baud
rate).
May indicate any of the following:
Loss of signal
Loss of signal inverted
Transmission fault
Transmission disable
Indicates the length of link using single form fiber.
Indicates the length of link using 50um multi-mode fiber.
Description
Port Management
259

Advertisement

Table of Contents
loading

Table of Contents