Using The Threshold Configuration Tab; Configuring Boundary And Alarm Settings; Enable/Disable Alarm Configurations - HP A7340A - Surestore FC 1Gb/2Gb Switch 16B User Manual

Hp storageworks web tools v3.1.x/4.1.x user guide (aa-rs25c-te, june 2003)
Hide thumbs Also See for A7340A - Surestore FC 1Gb/2Gb Switch 16B:
Table of Contents

Advertisement

Using the Threshold Configuration Tab

Use the Configuration tab to configure and view alarms as shown in the following
sections.

Configuring Boundary and Alarm Settings

1. Launch Fabric Watch (see
2. Select the Threshold Configuration tab.
3. Select the Area Configuration sub-tab.
4. Highlight an element in the navigation tree.
5. Select an Area (such as temperature or fan) from the Area drop-down menu.
6. Configure the Threshold Settings.
7. Configure the Alarm Settings.
8. (Optional) Check the Flash box to update the flash memory.
9. Click the Apply button.
10. Enable Alarms (see

Enable/Disable Alarm Configurations

1. Launch Fabric Watch (see
2. Select the Threshold Configuration tab.
3. Select the Element Configuration sub-tab.
4. Select a previously configured element from the navigation tree (see
5. Select the alarm area to be enabled or disabled from the Area drop-down
6. Select the Element Configuration tab.
7. Select the alarm Element to be enabled/disabled from the Select Element
8. Select the Enable or Disable radio button.
9. Click the Apply button.
Web Tools Version 3.1.x/4.1.x User Guide
You can select a whole device (such as a Switch) or an element of that device
(such as Security).
"Enable/Disable Alarm
"Configuring Boundary and Alarm
menu.
drop-down menu.
"Launch Web
Tools." on page 173).
Configurations" on page 181).
"Launch Web
Tools." on page 173).
Settings" on page 181).