Installing The Current Fibre_Scsi Patch On The Servers - HP AD510A - StorageWorks Modular Smart Array 1500 cs 2U Fibre Channel SAN Attach Controller Shelf Hard Drive Installation Manual

Modular smart array
Hide thumbs Also See for AD510A - StorageWorks Modular Smart Array 1500 cs 2U Fibre Channel SAN Attach Controller Shelf Hard Drive:
Table of Contents

Advertisement

Installing the current Fibre_SCSI patch on the servers

1.
Download the current patch from the HP OpenVMS Systems website:
http://h71000.www7.hp.com/serv_support.html.
a. Navigate to the HP Proactive service tools banner.
b. Select one of the following options:
• Register to access the HP Patch Database
• FTP site for OpenVMS patches
c. Follow the onscreen instructions to navigate to and download the patch.
Table 1 1
OpenVMS Fibre_SCSI patches (as of August 2006)
OpenVMS version
OpenVMS 7.3-2
OpenVMS 8.2 (Alpha)
OpenVMS 8.2 (Itanium)
OpenVMS 8.2- 1 (Itanium)
2.
For existing OpenVMS installations:
a. Assign a unique identifier to the MSA controller. For instructions, see the MSA1000/1500
Command Line Interface user guide.
b. On each OpenVMS server, install the Fibre_SCSI patch on all system disks. For instructions,
see the documentation that came with the kit.
3.
If you do not have an existing OpenVMS installation:
a. Create at least one LUN on the MSA. For instructions, see the MSA1000/1500 Command
Line Interface user guide.
b. Assign a unique identifier to the MSA controller. For instructions, see the MSA1000/1500
Command Line Interface user guide.
c. Install OpenVMS on the server. For instructions, see your version-specific OpenVMS upgrade
and installation manual.
d. Install the Fibre_SCSI patch on all system disks. For instructions, see the documentation that
came with the kit.
e. Restart the OpenVMS server.
Fibre_SCSI patch
VMS732_FIBRE_SCSI-V0900
VMS82A_FIBRE_SCSI-V0200
VMS82I_FIBRE_SCSI-V0200
VMS821I_FIBRE_SCSI-V0200
HP StorageWorks 1500 Modular Smart Array installation guide