1.
Set the SCSI ID so that there are no duplicates between SCSI devices
on the same SCSI bus.
2.
The priority of SCSI bus use in ARBITRATION phase is determined by
SCSI ID as follows:
7 > 6 > 5 > 4 > 3 > 2 > 1 > 0 > 15 > 14 > 13 > 12 > 11 > 10 > 9 > 8
5.3.2
Each mode setting
(1)
Setting terminal power supply
Refer to Table 5.2 for controlling the supply of power from the drive to the SCSI terminal resistance
power source (TERMPOW). However, this setting may not be used with SCA2 type 16 bit-SCSI
(LC/MC). For information on LP/MP, refer to Figures 5.2 and 5.3.
Table 5.2
Supply on/off of SCSI terminating resistor power from IDD
*1 Setting at factory shipment
Table 5.1
SCSI ID setting (CN2)
SCSI ID
7-8
0
Open
1
Open
2
Open
3
Open
4
Open
5
Open
6
Open
7
Open
8
Short
9
Short
10
Short
11
Short
12
Short
13
Short
14
Short
15 (*1)
Short
*1 Set at factory shipment
IMPORTANT
Setting SCSI terminal power supply (LP/MP)
Supply off
Supply on
C141-E064-03EN
CN2
5-6
3-4
1-2
Open
Open
Open
Open
Open
Short
Open
Short
Open
Open
Short
Short
Short
Open
Open
Short
Open
Short
Short
Short
Open
Short
Short
Short
Open
Open
Open
Open
Open
Short
Open
Short
Open
Open
Short
Short
Short
Open
Open
Short
Open
Short
Short
Short
Open
Short
Short
Short
CN2 23-24
Open
Short (*1)
5 - 7