5.4

Mounting Drives

5.4.1

Check before mounting

Reconfirm if the setting terminals are set correctly according to Table 5.8 before mounting the
drive in the system cabinet. For setting terminals location, see Section 5.3.
Setting
No.
terminal
1
SCSI ID
CN2
2
Write protect
3
Motor start mode
4
Force Narrow
5
Force single ended
6
Terminal power supply
5.4.2

Mounting procedures

Since mounting the drive depends on the system cabinet structure, determine the work
procedures considering the requirements specific to each system. The general mounting
method and items to be checked are shown below.
See Subsection 4.2 for the details of requirements for installing the IDD.
1) With a system to which an external operator panel is mounted, if it is difficult to access the
connector after the drive is mounted on the system cabinet, connect the external operator
panel cable before mounting the drive.
2) Fix the drive in the system cabinet with four mounting screws as follows:
The drive has 10 mounting holes (both sides: 3 2, bottom: 4). Fix the drive by
using four mounting holes of both sides or the bottom. (See Figure 4.9)
Use mounting screws whose lengths inside the drive mounting frame are 4 mm or less
when the screws are tightened (see Figure 4.8).
When mounting the drive, be careful not to damage parts on the PCAs.
3) Check to ensure that the DE is not touching the frame on the system side after tightening
the screws. At least 2.5mm of clearance is required between the DE and the frame.
(Indicated in Figure 4.8)
4) When an electric driver is in use, less than low-impact device specifications must be used.
5 - 10
Table 5.8

Setting check list

Setting contents
(Check item)
CN2
CN2 9 - 10
CN2 11 - 12
CN2 13 - 14
CN2 15 - 16
CN2 23 - 24
C141-E064-03EN
Setting
Check
position
7 - 8
(SCSI ID = __)
5 - 6
3 - 4
1 - 2
Short
Short
Short
Short
Short
Remarks
Upper bus
(DB 8 to 15
PI)
not connected
Open
Open
Open
Open
Open LP/MP models