Wsw24 - Brother IntelliFax-4750 Service Manual

Facsimile equipment
Hide thumbs Also See for IntelliFax-4750:
Table of Contents

Advertisement

Selector
No.
1
Not used.
2
3
Time length from CML ON to
start of pseudo ring backtone
4
transmission
Attenuator for playback of ICM/
5
OGM to the line
|
(Selectable from the range of 0-
8
15 dB)
l
Selectors 3 and 4: Time length from CML ON to start of pseudo ring backtone transmission
These selectors set the length of time from CML-ON up to the start of pseudo ring backtone
transmission.
In those versions which have an OGM facility, the settings made by these selectors also apply to
the length of time from CML-ON up to the start of OGM transmission.
Selectors 5 through 8: Attenuator for playback of ICM/OGM to the line
l
Setting two or more selectors to "1" produces addition of attenuation assigned to each selector.
This setting will not be limited by selector 8 of WSW23.

WSW24

(TAD setting 2)
Function
V - 36
Setting and Specifications
No.
3
4
0
0
:
0
1
:
1
0
:
1
1
:
0:
0 dB
0:
0 dB
0:
0 dB
0:
0 dB
4 sec.
3 sec.
2 sec.
1 sec.
1:
8 dB
1:
4 dB
1:
2 dB
1:
1 dB

Advertisement

Table of Contents
loading

Table of Contents