Replacing Hot-Swap Fans - IBM 8841 - eServer xSeries 236 Option Installation Manual

Installation guide
Hide thumbs Also See for 8841 - eServer xSeries 236:
Table of Contents

Advertisement

Replacing hot-swap fans

The server comes with four hot-swap fans: two front fans (fans 1 and 2), and two
center fans (fans 3 and 4). You do not have to turn off the power to the server to
replace a hot-swap fan.
If the server is equipped with the IBM xSeries 670-Watt Hot-swap Power-Supply
option, two rear fans (fans 5 and 6) must also be installed on the server. For
information on replacing these fans or installing this option, see "Replacing a rear
fan (5 or 6)" on page 21 or "Installing the 670-Watt hot-swap power-supply option"
on page 23.
Attention:
The following illustration shows how to replace hot-swap fans.
Determine which fan to replace by checking the LEDs on the fans. The front fans,
center fans, and rear fans are installed differently from each other. This section
contains separate instructions for each group of fans.
To help ensure proper cooling, if a fan fails, replace it within 48 hours.
Front fan
1 or 2
Center fan
3 or 4
Release
lever
Hot-swap fan
Hot-swap fan
assembly
Chapter 2. Installing options
19

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xseries 236 8841

Table of Contents