Complete the following steps to replace hot-swap-fans 5 and 6:
1. Read the safety information beginning on page v and "Installation guidelines" on
2. Press in on the orange fan-release latch on the side of the fan; then, rotate the
3. Pull the fan off the server.
4. Slide the two tabs of the replacement fan into the back of the server; then,
5. Make sure that the FAN LED on the diagnostic LED panel (see the Hardware
22
IBM xSeries 236 Type 8841: Option Installation Guide
page 11.
fan away from the server.
rotate the fan toward the server until the fan-release latch clicks.
Maintenance Manual and Troubleshooting Guide on the IBM xSeries
Documentation CD for the location of the LED) is not lit. If the FAN LED is lit,
reseat the fan.
Rear fan 5 or 6
Fan-release
latch