IBM 8841 - eServer xSeries 236 Option Installation Manual page 37

Installation guide
Hide thumbs Also See for 8841 - eServer xSeries 236:
Table of Contents

Advertisement

b. Slide the power supply into the power supply 2 opening until it stops; then,
push the handle down into the closed position.
4. Install the fans on the back of the server:
a. Position the first fan so that the notched area is facing up and the mounting
surface is toward the server.
b. Tilt the bottom of the fan toward the server and insert the tabs into the
corresponding holes.
c. Press in on the top half of the fan until it clicks into place.
d. Position the second fan so that the notched area is facing down and the
mounting surface is toward the server.
e. Repeat steps 5b and 5c; then, continue to step 6.
5. Connect one end of each power cord to the corresponding connector on each
power supply; then, connect the other end of each power cord to a properly
grounded electrical outlet.
Note: You can route the power cords through the power-cord restraint bracket
on the rear of the server.
6. Make sure that the dc power LED and the ac power LED on each power supply
is lit, indicating that the power supplies are operating properly.
Chapter 2. Installing options
25

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xseries 236 8841

Table of Contents