Light Path Diagnostics Panel - IBM 8841 - eServer xSeries 236 Option Installation Manual

Installation guide
Hide thumbs Also See for 8841 - eServer xSeries 236:
Table of Contents

Advertisement

Light path diagnostics panel

The following illustration shows the remind button and the LEDs on the light path
diagnostics panel. The light path diagnostics panel is inside the server under the
left-side cover and the error LEDs are also visible through the left-side cover.
Use the remind button on the light path diagnostic panel to acknowledge that an
error has occurred without taking further action. When you push the remind button,
the system error LED will flash every 2 seconds until the error is fixed. If another
error occurs, the system error LED will then stop flashing and return to a solid on
state.
For more information about light path diagnostics, see the Hardware Maintenance
Manual and Troubleshooting Guide on the IBM xSeries Documentation CD.
The following table lists the light path diagnostics LEDs, the problems that they
indicate, and actions to solve the problems.
LED
Problem
POWER SUPPLY 1
Lit LED: Power supply 1 has failed. 1. Remove ac power from the server.
Flashing LED: Power supply 1 was
removed in a redundant
power-supply configuration.
POWER SUPPLY 2
Lit LED: Power supply 2 has failed. 1. Remove ac power from the server.
Flashing LED: Power supply 2 was
removed in a redundant power
supply configuration.
MEMORY
A memory error has occurred.
CONFIG
See the note following this table.
8
IBM xSeries 236 Type 8841: Option Installation Guide
1
POWER
SUPPLY
2
MEMORY
DASD/
CONFIG
RAID
TEMP
FAN
PCI
BUS
CPU
S_ERR
VRM
SERVICE
NMI
PROCESSOR
BUS
Action
2. Replace the power supply; then, reconnect the server
Install a new power supply in the PS1 location.
2. Replace the power supply; then, reconnect the server
Install a new power supply in the PS2 location.
Replace the failing DIMM, indicated by the lit LED on the
system board.
See the note following this table.
REMIND
to ac power and restart the server.
to ac power and restart the server.