Immunities; Electrostatic Discharge (Esd) Immunity; Radiated Immunity; Table 29 Electrostatic Discharge (Esd) Immunity Limits - Tandberg Data DLT-V4 Product Specification

Hide thumbs Also See for DLT-V4:
Table of Contents

Advertisement

Immunities

Electrostatic Discharge
(ESD) Immunity
Table 29 Electrostatic
Discharge (ESD) Immunity
Limits

Radiated Immunity

DLT-V4 Product Specification
The tape drive meets the following standards:
EMC Directive (89/336/EEC)
EN 55024: 1998 Information Technology Equipment – Immunity
(reference the basic standard IEC 61000–4–n)
IEC/CISPR 22: 1997, +A1: 2000, +A2: 2003 Class B Information
Technology Equipment – Immunity
The tape drive meets the ESD immunity limits per EN 61000–4–2: 2001
listed in
table 29
7
Specification
Contact discharge 8 kV
Air discharge 10 kV
Air discharge (stress) 15 kV
±
Survival 25 kV
The product meets the product reliability levels (air discharge
Note:
to 10 kV, with 15 kV desired).
The tape drive meets the radiated immunity limits per EN 61000–4–3:
7
2002 listed in
table
Chapter 7 Emission and Immunity Specifications
for operator access areas of the tape drive.
Performance Criteria
±
No operator intervention
±
(soft recoverable errors allowed)
±
No physical damage
30.