Brother 8250P - FAX B/W Laser Printer Service Manual page 133

Facsimile equipment
Table of Contents

Advertisement

Selector
No.
1
Definition of programmable key
2
Ringer OFF setting
Automatic playback of OGM at the
3
start time of OGM ON mode
Detection of distinctive ringing
4
pattern
5
Not used.
6
Recording quality level
Sampling rate when the recording
7
quality level is set to High
8
Toner save mode
NOTE: Selector 1 is not applicable to the U.S.A. versions.
NOTE: Selectors 3, 6 and 7 are applicable to those models equipped with a built-in TAD.
Selector 1:
Definition of programmable key
l
This selector defines a programmable key as a TEL key or TEL/POLLING key.
Setting this selector to "1" allows the programmable key to function as either a TEL or POLLING
key if pressed when the handset is off or on the hook, respectively.
This setting is effective only for those models having a programmable key.
Selector 2:
Ringer OFF setting
l
This selector determines whether or not the ringer can be set to OFF.
l
Selector 3:
Automatic playback of OGM at the start time of OGM ON mode
This selector determines whether or not the equipment automatically plays back an OGM the
moment it switches to the OGM ON mode in the MC mode.
l
Selector 4:
Detection of distinctive ringing pattern
If this selector is set to "1" the equipment detects only the number of rings; if it is set to "0" the
equipment detects the number of rings and the ringing time length to compare the detected ringing
pattern with the registered distinctive one.
Selector 6:
Recording quality level
l
This selector determines the recording quality level (this function can be accessed also by the user
function 8-8).
If it is set to "0" (Normal), the sampling rate specified by selector 4 of WSW30
takes effect; if it is set to "1" (High), the sampling rate by selector 7 of WSW27 takes effect.
Selector 7:
Sampling rate when the recording quality level is set to Normal
l
This selector determines the sampling rate when selector 6 of WSW27 is set to "1" (High). If this
selector is set to "0," the sampling rate is 9.6 kbps; if it is set to "1," the sampling rate is 8.8 kbps.
WSW27
(Function setting 5)
Function
V - 40
Setting and Specifications
0:
TEL key
1:
0:
Yes
1:
0:
No
1:
0:
Yes
1:
0:
Normal
1:
0:
Short
1:
0:
Yes
1:
TEL/POLLING key
No
Yes
No
High
Long
No