The standard Wiegand wiring colours for ACTpro MIFARE classic readers are shown below.
Reader PIN Description
Sense
Clock / D1
Data / D0
12-24 V DC
0 V
Red
Green
Wiring for Entry / Exit "Wiegand" Readers
Wiring Information for "Wiegand" Output
Recommended wiring colour
White
Green
Blue
Red
Black
Brown
Yellow
Description
Direction – connect for entry
Clock / D1
Data / D0
+ Voltage
- Voltage
Red LED
Green LED
Wiring for "Wiegand" Entry Reader
Colour
White
Green
Blue
Red
Black
Brown
Yellow
Wiring for "Wiegand" Exit Reader
Colour
White
Green
Blue
Red
Black
Brown
Yellow
4
Rev 1.0
Controller Pin
0V
CLOCK / D1
DATA / D0
+12V
0V
RED
GREEN
Controller Pin
0V
CLOCK / D1
Sense
+12V
0V
RED
GREEN