Troubleshooting iLO 2

iLO 2 POST LED indicators

During the initial boot of iLO 2, the POST LED indicators flash to display the progress through the iLO 2
boot process. After the boot process is complete, the HB LED flashes every second. LED 7 also flashes
intermittently during normal operation.
The LED indicators (1 through 6) light up after the system has booted to indicate a hardware failure. If a
hardware failure is detected, reset iLO 2. For the location of the LED indicators, refer to the server
documentation.
A runtime failure of iLO 2 is indicated by HB and LED 7 remaining in either the On of Off state constantly.
A runtime failure of iLO 2 can also be indicated by a repeated flashing pattern on all eight LEDs. If a
runtime error occurs, reset iLO 2.
A sequential flashing pattern on LEDs, 1, 2, 3, 4, 5, 6, 7, and 8, repeating indefinitely, indicates iLO 2
has experienced a failed flash (firmware upgrade) and is in the flash recovery mode. Refer to the "iLO
network flash recovery" section for more information.
The LED indicators have the following assignments:
HB
7
6
LED indicator
None
1 or 2
2 and 1
3
3 and 2
3, 2, and 1
4
4 and 1
4 and 2
4, 2, and 1
4 and 3
5
4
3
2
1
POST code
(activity
completed)
00
02—Normal
operation
03
04
06
07
08
09
0a
0b
0c
Description
Set up chip selects.
Determine platform.
Set RUNMAP bit.
Initialize SDRAM controller.
Activate the I cache.
Initialize (only) the D cache.
Copy secondary loader to
RAM.
Verify secondary loader.
Begin secondary loader.
Copy ROM to RAM.
Verify ROM image in RAM.
Failure indicated
Could not copy secondary
loader.
Did not execute secondary
loader.
SDRAM memory test
failed.
Could not copy boot
block.
Boot block failed to
execute.