3-24 Compaq ProLiant 8000 Intel Pentium III Xeon 700MHz Servers Maintenance and Service Guide
Table 3-2
POST Error Messages
Error Code
1775-Slot X Drive
Array - ProLiant
Storage System Not
Responding SCSI
Port Y: Check storage
system power switch
and cables. Turn the
system power off
while checking the
ProLiant power and
cable connections,
then turn the system
power back on to
retry.
1776-Slot X Drive
Array – SCSI Bus
Termination Error –
Internal and external
drives cannot both be
attached to the same
SCSI port.
SCSI port Y: Check
cables
RESUME = F1 Key
continued
Audible Beeps
Probable Source of Problem
None
Storage system problem
detected.
None
External and internal connectors
of the specified SCSI ports are
both attached to drives. The
indicated SCSI bus is disabled
until this problem is resolved.
Recommended Action
Turn off power to system.
Check external ProLiant power
switch – external drives must all
be powered up before or at the
same time as the main system.
Check cables. If retry does not
help, try replacing the cable,
firmware, backplane, or the
Smart Array Controller.
The SCSI bus is not properly
terminated when internal and
external drives are attached
concurrently to the same SCSI
bus.
1.
Turn off power to the
server.
2.
Verify cabling to the
specified port.
3.
Reconfigure drives as
indicated.
continued