Compaq Network Interface Cards
Test Error Codes
The 6000 series of Diagnostic error codes identifies failures with
32-bit DualSpeed NetFlex-2/Token Ring Controllers. Corrective action may require
replacement of the 32-bit DualSpeed NetFlex-2/Token Ring Controller.
Error Code
6000-xx
6001-xx
6002-xx
6014-xx
6016-xx
6028-xx
6029-xx
6089-xx
6090-xx
6091-xx
6092-xx
Compaq Network Interface Cards
Test Error Codes
Description
Network card ID failed.
Network card setup failed.
Network card transmit failed.
Network card configuration failed.
Network card reset failed.
Network card internal failed.
Network card external failed.
Network card open failed.
Network card initialization failed.
Network card Internal loopback failed.
Network card external loopback
failed.
Compaq ProLiant 1600 and ProLiant 1200 Servers Maintenance and Service Guide
Table 3-14
Recommended Action
The following steps apply to error
codes 6000-xx through 6089-xx:
1. Check the controller
installation in the EISA slot.
2. Check the interrupt type and
number setting.
3. Check the media connection
at the controller and
Multistation Access Unit
(MAU)*.
4. Check the media speed
(4/16 ) and type Unshielded
Twisted Pair/Shielded Twisted
Pair (UTP/STP) settings.
5. Check the MAU, cabling, or
other network components.
6. Replace the controller.