Gas And Electrical Rough-In - Electrolux E48DF76EPS - 48" Pro-Style Dual-Fuel Range Installation Instructions Manual

Dual fuel ranges
Hide thumbs Also See for E48DF76EPS - 48" Pro-Style Dual-Fuel Range:
Table of Contents

Advertisement

GAS AND ELECTRICAL ROUGH-IN

Locations
NO
NO
TE
TE
NO
NO
NOTE
TE
TE
The shaded areas shown in the illustrations, denote the location of the gas stub and the
electrical junction box/receptacle. These are suggested locations. For replacement
purposes, the location of the existing utilities may be utilized provided that they do not
interfere with the sides or rear of the range. If installing the gas valve behind the range,
verify that local building codes will permit this.
A manual shut valve must be installed in the gas piping, external to the appliance,
for the purpose of turning on or shutting off gas to the appliance. Plan the location
of the range and the gas supply to allow access to the valve when the unit is
installed. Access to the remote circuit breaker panel/fuse box, with the range in
place, must also be allowed for in the installation. Any openings in the wall behind
the appliance and in the floor under the appliance must be sealed.
Both the gas supply piping and shut-off valve, and the electrical junction box/
receptacle must be located so they do not interfere with the range when it is
installed. In addition, the junction box must be located so the range can be removed
for service when the conduit supplied with the unit is attached to the junction box.
Do not lengthen the conduit or wiring provided with the range.
All dimensions shown are based on standard American cabinets 36 inches
(914mm) high at the finished countertop by 24 inches (610mm) deep, with a 25
inch (635mm) overall countertop depth. When installing the range into nonstandard
cabinets, minimum clearances shown in the diagrams on page 11 must be
maintained.
Carefully check the location where the range is to be installed. For best
performance, the range should be placed away from drafts that may be caused by
doors, windows and HVAC outlets.
Preparing for Installation
9

Advertisement

Table of Contents
loading

This manual is also suitable for:

E30df74epsE36df76epsE48df76eps

Table of Contents