Conversion Back to Natural Gas
If it is necessary to return the range to natural gas service, repeat all of the steps in this procedure using the
parts that have been removed. Use the chart below to determine the orifice sizes, shutter gaps, and the air
shutter part numbers.
Natural Gas Conversion Specifications
Burner
Location
Left Rear
Left Front
Right Rear
Right Front
Burner
Location
Left Rear
Left Front
Right Rear
Right Front
Center Rear
Center Front
Burner
Location
Left Rear
Left Front
Right Rear
Right Front
Center Rear
Center Front
The Electrolux Group
USA • 250 Bobby Jones Expressway • Augusta, GA 30907
1-877-4electrolux (1-877-453-3287) • www.electroluxusa.com
CANADA • 5855 Terry Fox Way • Mississauga, ON L5V 3E4
1-800-688-4606 • www.electroluxca.com
Bypass
Main
Orifice
Orifice
81
72
81
81
Model E30DF74EPS (30-Inch)
Bypass
Main
Orifice
Orifice
81
72
72
81
81
81
Model E36DF76EPS (36-Inch)
Bypass
Main
Orifice
Orifice
81
72
72
81
81
81
Model E48DF76EPS (48-Inch)
Page 12
Air Shutter
Part No.
184
HN A-0053-E
140
HN A-0052-E
184
HN A-0053-E
188
HN A-0053-E
Air Shutter
Part No.
184
HN A-0053-E
133
HN A-0052-E
133
HN A-0052-E
184
HN A-0053-E
196
HN A-0053-E
196
HN A-0053-E
Air Shutter
Part No.
184
HN A-0053-E
133
HN A-0052-E
133
HN A-0052-E
184
HN A-0053-E
196
HN A-0053-E
196
HN A-0053-E
Air Shutter
Gap (IN/MM)
.37/9.5
.34/8.6
.35/8.9
.37/9.4
Air Shutter
Gap
.37/9.5
.30/7.6
.33/8.4
.37/9.4
.38/9.6
.37/9.5
Air Shutter
Gap
.38/9.6
.35/8.8
.30/7.7
.39/9.9
.38/9.7
.37/9.5