Installation Specifications; Electrical Specifications; Planning The Installation - Dacor ERV30 Installation Instructions Manual

Downdraft raised vent
Hide thumbs Also See for ERV30:
Table of Contents

Advertisement

WARNING
Observe all governing codes and ordinances during
planning and installation. Contact your local building
department for further information.
The electric outlet for the raised vent should be
installed only by a licensed electrician.

Electrical Specifications

The raised vent is supplied with a 28" (711 mm) power
cord terminated by a three-prong plug. Plug it directly into a
dedicated, grounded, three prong, electrical outlet. Do not
use an extension cord.
The correct voltage, frequency and amperage must be sup-
plied to the electrical outlet from a grounded, single phase
circuit that is protected by a properly sized circuit breaker
or time-delay fuse.
Electrical Supply Requirements
A three-prong electrical outlet connected to a 120
Vac, 60 Hz, 15 Amp. grounded, dedicated circuit is
required.
The customer must supply wiring/conduit with mini-
mum current carrying capacity of 8 Amps. to supply
power to the remote or in-line blower from the raised
vent. See General System Layout and Planning
the Duct Work for further details.
The above specifications are for reference only. If the
power supply requirements shown above do not agree
with those listed on the product data label, use the
required voltage, frequency and amperage ratings on
the label.
It is the owner's responsibility to ensure that electrical
outlet is installed by a licensed electrician. The electri-
cal installation must comply with the latest revision of
the National Electric Code ANSI/NFPA 70* (latest revi-
sion) and local codes and ordinances.
*A copy of this standard may be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, Massachusetts 02269-9101
Locate the electrical outlet in an accessible location,
so that the power plug can be disconnected for service
without removing the raised vent or the range from the
cabinet.
4

Installation Specifications

Planning the Installation

General System Layout
The vent system consists of the raised vent itself and a sin-
gle Dacor approved remote or in-line blower (see page 6).
WARNING
Failure to install an approved remote or in-line blower
or proper duct work will result in a back draft and/or
the insufficient venting of smoke and fumes.
To reduce the risk of personal injury caused by reach-
ing over a hot appliance, cabinet storage space locat-
ed directly above the range should be avoided.
Do not store combustible materials or items adversely
affected by heat in cabinet areas above the appli-
ance.
Follow the instructions and diagrams for minimum
safe clearances and installation location in these
instructions, the appliance installation instructions and
the remote or in-line blower installation instructions.
Failure to do so may result in a fire or safety hazard.
Wire the remote or in-line blower to turn on when the
raised vent is turned on by running wiring/conduit paral-
lel to the duct work and connecting it to the raised vent
on one end and the blower on the other. There are 7/8"
access holes in the bottom and side of the raised vent
for connecting the conduit/strain relief.
Front of unit
Blower wiring access
hole in bottom
Electrical Access Hole Locations for Blower
Connection
Blower wiring
access hole in
side