Installation Instructions; Installation Preparation; Installation; Verify Package Contents - Dacor ERV30 Installation Instructions Manual

Downdraft raised vent
Hide thumbs Also See for ERV30:
Table of Contents

Advertisement

Installation Preparation

Verify Package Contents

Product literature
Anchoring legs
2 wood screws, #14 x 2 1/2 (PN 83047)
3 wire nuts
ADT2 duct transition
2 sheet metal screws, #10 x 1/2 (PN 83022)
2 keps nuts, 1/4-20 (PN 83049)
2 flat washers, 1/4-20 (PN 83203)
Insulation foam

Installation

WARNING
If the electrical service (electrical outlet) does not
meet the Electrical Specifications on page 4, do not
proceed with the installation. Call a licensed electri-
cian and have an electrical outlet installed that meets
the specifications.
Install the vent only in a vertical orientation. Do not
mount the vent on a slant or angle.
Do not enlarge or modify the exhaust knock outs or
cut an exhaust hole in a location on the chassis other
than those shown. Doing so may cause an increase
in noise and decrease performance.
NOTE: The ERV series raised vent installs in the back of
the cutout, separate from the range. Install the raised vent
before pushing the range into place.
Installing the Raised Vent
1.
Remove the appropriate side, back or bottom exhaust
knockout, depending on the desired exhaust configura-
tion, from the raised vent chassis by cutting the metal
cross overs and removing the insert.
Back of unit
Side
knock-out
Rear knock-out with
Vent Knock-out Locations - Rear View
8

Installation Instructions

Side
knock-out
metal cross overs
shown
Bottom knock-out
2.
Cut and remove the foil material inside the knock-out
hole. If you fail to remove the foil, the vent will not work.
3.
If the unit will vent through the bottom or side:
Attach the supplied ATD2 transition to exhaust
location with the provided sheet metal screws.
ADT2 bottom
installation
ADT2 Transition Installation
For bottom installations cut a hole in the cabinet
floor to allow the exhaust transition and/or the duct
to pass through the floor.
Cut hole in floor to allow
duct to pass through on
bottom venting installations
Floor
4.
If the unit will exhaust air from the back, attach a
3 1/4" X 10 duct to the vent hole created by removing
the knock-out on the back of the unit.
ADT2 side
installation
Attach sealing
foam
Top of vent resting
on countertop

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Erv36Erv48Erv36-erErv48-er

Table of Contents