Cf_Pipmodefree Command; Cf_Piprst Command; Cf_Edgeblending Command; Cf_Blend Command - Sanyo PDG-DHT8000L - 8000 Lumens Specifications

Expand serial command functional specifications
Hide thumbs Also See for PDG-DHT8000L - 8000 Lumens:
Table of Contents

Advertisement

PDG-DHT8000L Expand Serial Command Functional Specifications

8.9.15 CF_PIPMODEFREE Command

Command
"CF_PIPMODEFREE_%1" [CR]
"USER1" --------------------------- Set User1 to Free status
"USER 2" -------------------------- Set User2 to Free status
%1
"USER 3" -------------------------- Set User3 to Free status
"USER 4" -------------------------- Set User4 to Free status
"USER 5" -------------------------- Set User5 to Free status
Delete the data registered in Custom User1–5 and returns it to Free status.
This command operates the same way as resetting to User1-5 in "Picture in
Details
Picture" Menu.
(Available only in the normal Power ON status)
*When there is only one user mode of stored state, return "101" [CR]
Acceptable
Response
Unacceptable

8.9.16 CF_PIPRST Command

Command
"CF_PIPRST_%1" [CR]
%1
"RST" ---------------------- Reset current setting status
Reset current setting status of "Picture in Picture".
Details
(Available only in the normal Power ON status)
Acceptable
Response
Unacceptable

8.9.17 CF_EDGEBLENDING Command

Command
"CF_EDGEBLENDING_%1" [CR]
"ON" ---------------------- Set Edge blending to On
%1
"OFF" -------------------- Set Edge blending to Off
Set Edge blending.(Available only in the normal Power ON status)
Details
The status set by this command is stored in EEPROM and setting remains
effective even after the power is turned to ALL OFF status.
Acceptable
Response
Unacceptable

8.9.18 CF_BLEND Command

Command
"CF_BLEND_%1_%2" [CR]
"LEFT" ---------------------- Left side
"RIGHT" -------------------- Right side
%1
"TOP" ----------------------- Upper side
"BOTTOM" ---------------- Lower side
"000"-"960"-------------------- Directly specify value of direction of %1
*Value of upper limit changes by choice of %1
Left ---------------------- 000~960
%2
Right -------------------- 000~960
Top ---------------------- 000~540
Bottom ----------------- 000~540
Set value of direction specified by Edge blending %1.
(Available only in the normal Power ON status)
Details
The status set by this command is stored in EEPROM and setting remains
effective even after the power is turned to ALL OFF status.
Acceptable
Response
Unacceptable
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]
43/101