Network and Security Manager 2010.3 Release Notes

Secure Access SSL VPN SA Series and United Access Control Infranet Controllers

32
464396—On a modeled ScreenOS root device with a modeled vsys device, NSM does
not display the IPv6 option on the modeled vsys.
464517—When a rule is added to a policy and the Notify Closed Session option is
enabled, NSM shows the 'unset IDP' command in the delta configuration. If IDP is
enabled on the device, IDP does not get unset.
465144—NSM does not display the option to monitor the IDP security module under
the VSD group monitoring section.
478268—An update to an SRX Series device fails if the Confirmed commit option is
enabled in the GUI.
479370—NSM does not generate dead peer detection configuration for IKE gateways
on SRX Series devices.
489282—When you update an SSG5 running ScreenOS 6.1, NSM unsets eth0/0 and
BGP even when an eth 0/0 change is unnecessary and BGP is not enabled. The
workaround is to enable BGP on tunnel 1.1.
497114—Updates to an SRX3600 device fail because NSM repeatedly displays a
hardware OutofSync message. The workaround is to manually right-click on the device
and reconcile inventory.
497120—Updating an SRX3600 device with an IDP policy fails, displaying a 'Previous
commit is in progress' error message. The workaround is to wait for several minutes
until the back-end commit process is completed.
518101—Validating a device fails after adjusting the OS version or updating the software
through NSM.
521642—NSM displays delta configuration for ISG devices after the OS version is
adjusted from 6.1 to 6.3.
522885—While adding SOS devices on an NSM HA server, a DB_EVENT_PANIC error
message is displayed, and the HA server fails over to the secondary server. This issue
is seen occasionally.
522890—Editing a ScreenOS cluster device, with a device configuration of 275 KB,
takes approximately 5 minutes.
523203—ISG-1000 devices running ScreenOS 6.3r3 display a validation error under
the root profile.
436750—NSM cannot import an IC if the IC has more than 5100 resource access
policies. The import operation does not complete.
455844—Deleting an SA device object from NSM does not remove the object until
services are restarted. This is seen intermittently.
460586—When a Junos OS SA/IC template is removed from a device, the template
values are not retained even if the Retain Template values on removal option is
checked.