Designed for use on SWG Series
Power Vent Hoods for controlling oil
fired heating appliances with 120 VAC
controls.
The CK-63 control has the ability to
operate the oil burner motor (up to 1/3
HP) and the venter at the same time.
This allows for shorter post purge time.
This feature requires the burner to be
equipped with a delayed oil solenoid
valve, which is not supplied with this
kit.
I
TEMS INCLUDED IN KIT
1)
Junction box with mounted pressure switch
and
solid state post purge control
1)
2 Ft. Length of ¼ inch aluminum tubing
1)
¼ inch tubing connector
1)
Flexible conduit connector
1)
WMO-1 Blocked Vent Switch
1)
Thermostat Resistor Kit
This device MUST be installed by a qualified agency* in accordance with the manufacturer's installation instructions.
The definition of a qualified agency is: any individual, firm, corporation or company which either in person or through a
representative is engaged in, and is responsible for, the installation and operation of oil appliances, who is experienced
in such work, familiar with all the precautions required, and has complied with all the requirements of the authority
having jurisdiction.
WARNING:
Read the installation instructions carefully and completely before proceeding with the installation.
All wiring shall be in accordance with the National Electrical Code and applicable local codes
2630 Airport Road, Kinston, NC 28504 • Phone: 252-522-3031 • FAX: 252-522-0214 • www.fieldcontrols.com
120 VAC SYSTEM CONTROL KIT
:
DO NOT DESTROY
THESE INSTRUCTIONS MUST REMAIN WITH EQUIPMENT
Model: CK-63
.

Advertisement

loading

Summary of Contents for Field Controls 46400900

  • Page 1 120 VAC SYSTEM CONTROL KIT Model: CK-63 Designed for use on SWG Series Power Vent Hoods for controlling oil fired heating appliances with 120 VAC controls. The CK-63 control has the ability to operate the oil burner motor (up to 1/3 HP) and the venter at the same time.
  • Page 2 INSTALLATION OUNTING UNCTION The junction box can be mounted at the venter or remotely mounted away from the venter. (See Figure 1 & Figure 2) 1. Remove one of the knockouts from the side of the junction box where the pressure switch is mounted. Install the flexible conduit connector onto the CK-63 Junction Box and secure with fastening nut.
  • Page 3: Wiring Instructions

    WIRING INSTRUCTIONS Wire the venter motor and controls in accordance with the National Electrical Code, manufacturer's recommendations and/or applicable local codes. UNIT MUST BE GROUNDED. Check ground circuit to make certain that the unit has been properly grounded. The wiring should be protected by an over current circuit device rated at 15 amperes.
  • Page 4 Diagram B – Oil Fired System: Simultaneous Burner Wiring Diagram D Diagram C – Oil Fire System: Simultaneous Burner Wiring With – Oil Fired System: Wiring With Electronic Primary Electronic Primary Page 4...
  • Page 5 Diagram E – Typical Wiring for Oil Fired Warm Air Furnace with a Honeywell ST9103 Control Board Diagram F – Multiple Oil Fired Systems Page 5...
  • Page 6 Diagram G- 24V Gas Furnace Application Diagram H- Riello Burner Application Page 6...
  • Page 7 ADJUSTMENTS RESSURE WITCH DJUSTMENTS With the venter air flow set and the appliance operating at the best operating efficiency, adjust the pressure switch by rotating the adjustment screw clockwise until the burner shuts off, then rotate adjustment screw counterclockwise until the burner fires. Rotate the adjustment screw additional...
  • Page 8: Troubleshooting Hints

    TROUBLE SHOOTING HINTS 1. Main burner does not fire when thermostat calls for heat with venter operating. a. Check pressure switch adjustment. (LED should be lit when there is voltage from T1 – T2 and the pressure switch is closed.) b.
  • Page 9 CK-63 Wiring Aquastat Relay Check-Out Replacement Parts List Description Part Number Pressure Switch 46273100 Board Replacement Kit 46474300 (includes relay) WMO-1 46086900 Page 9...
  • Page 10 NOTES: Page 10...
  • Page 11 NOTES: Page 11...
  • Page 12 INSTALLATION INFORMATION CK-63 MODEL NO.: _____________________________________________________ INSTALLER'S NAME: ______________________________________________ INSTALLER'S COMPANY: __________________________________________ INSTALLER'S PHONE NO.: _________________________________________ DATE OF INSTALLATION: __________________________________________ For Technical Support, please call 1-800-742-VENT Page 12 PN 46400900 Rev I 08/05...

This manual is also suitable for:

Ck-63