Download Print this page

Field Controls 4615900 Instructions

Water heater control kit

Advertisement

Quick Links

WATER HEATER CONTROL KIT
Designed for use on SWG Series Power Venters for controlling Natural Gas
and L.P. Gas Instantaneous Water Heaters with a pressure tap port.
I
TEMS INCLUDED IN KIT
1) Junction box
1) Fan control gas pressure switch
1) 1 Ft. Length of 1/4 inch aluminum tubing
1) 1/8" NPT x 3 inch pipe nipple
1) 1/8" NPT x 1/4 inch OD tubing elbow
1) 1/8" NPT pipe tee
1) 6 Foot length of 12-2 wire
1) 8 Inch jumper wire
1) Flexible conduit connector
2) Spillage Switches
3) Adhesive Tabs
THESE INSTRUCTIONS MUST REMAIN WITH EQUIPMENT
Model: CK-21
:
DO NOT DESTROY

Advertisement

loading

Summary of Contents for Field Controls 4615900

  • Page 1 WATER HEATER CONTROL KIT Model: CK-21 Designed for use on SWG Series Power Venters for controlling Natural Gas and L.P. Gas Instantaneous Water Heaters with a pressure tap port. TEMS INCLUDED IN KIT 1) Junction box 1) Fan control gas pressure switch 1) 1 Ft.
  • Page 2 MOUNTING JUNCTION BOX The junction box can be mounted at the venter or remotely mounted away from the venter. (See Figure 1 & Figure 2) 1. Remove one of the knockouts from the side of the junction box where the pressure switch is mounted. Install the flexible conduit connector onto the CK-21 junction box and secure with fastening nut.
  • Page 3 WIRING Wire the venter motor and controls in accordance with the National Electrical Code, manufacturer's recommendations and/or applicable local codes. UNIT MUST BE GROUNDED. Check ground circuit to make certain that the unit has been properly grounded. The wiring should be protected by an over current device rated at 15 amperes. CAUTION must be taken to ensure that the wiring does not come into contact with any heat source.
  • Page 4 SYSTEM CHECK-OUT PROCEDURE FOR HOT WATER HEATER CONTROLS ATER EATER RESSURE WITCH 1. Following water heater manufacturer's instructions to light the pilot, turn the gas control valve to the ON position. 2. Open the hot water faucet; this should energize the venter. Next, close the hot water faucet; this should de-energize the venter.

This manual is also suitable for:

Ck-21