Download Print this page

Mobile Homes - Maytag JES9900BAF - 30" Electric Downdraft Installation Instructions Manual

Jenn-air electric downdraft range

Advertisement

Jenn-AirElectricDowndraftRange
PLEASEKEEPTHIS MANUAL FOR FUTUREREFERENCE
This manual is intended to assist in the initial installation and adjustments of the range.
• Onlyqualified personnel should install or service this range.
• Read "Safety Instructions" in Use& Care book before using range.
• Improper installation, adjustment, alteration, service, maintenance or use of range
can result in serious injury or property damage.
• Installer,take care not to damage flooring.
S
Do not lift or move range by grasping door handles or main top.
Thisrangehas been designed in accordancewith the
requirements of various safety agencies andcomplies with the
maximum allowable wood cabinet temperatures of 194°EIf this
range is installed with cabinets that have a lower working
temperature than 194°F, d iscoloration, delamination or melting
may occur.
Place range in a well lit area. Do notset range overholesin the
floor or other locations where it may be subject to strong
drafts.Any opening in the wall behind the range and in the
floor under the range should be sealed. Make sure the flow of
cooling/ventilation air is not obstructed below the range. Note:
A range should NOTbe installed over kitchen carpeting.
'All
RANGESCANTIP AND CAUSE
_J
INJURIES TO PERSONS,
INSTALL ANTI,TIP DEVICESPACKED
A risk of range tip-over exists if the appliance is not installed in
accordancewith the provided installation instructions. The proper use
of the ANTI-TIPdevice minimizes the risk of TIP-OVER. In using this
device the consumer must still observe the safety precautions as
stated in the USEand CAREMANUALand avoid using the ovendoors
as a step stool. Installation instructions are provided for wood and
cement in either floor or wall. Any other type of construction may
require special installation techniques as deemed necessaryto
provide adequatefastening of the ANTI-TIPbracket to the floor or wall.
The bracket must be installed to engage the RIGHT or LEFTrear
leveling foot. Install the bracket as shown in step 9.
MOBILE HOMES
The installationof a rangedesignedfor mobile homeinstallation mustconform with the ManufacturedHomeConstructionandSafetyStandard, T itle 24 CFR,
Part3280 (formerlythe FederalStandardfor Mobile HomeConstruction and Safety, T itle 24 HUD, P art 280)or,when suchstandard is not applicable,the
Standardfor ManufacturedHomeInstallationsANSIA225.1/NFPA 501A,or with local codes.In Canada the rangemust be installedin accordancewith the
current CSAStandardC22.1- CanadianElectricalCodePart 1.
| i: I: Id:1
The range must be installed in accordancewith Local and National
Electric Code(NEC)ANSI/NFPA No. 7O-latestedition, or Canadian
Electric CodeCSASTD.C221latest edition. Seerating plate for total
connected KW rating.
Your local utility company will tell you whether the present electric
service to your home is adequate. It may be necessaryto increase the
size of the wiring to the house and service switch to take care of the
electrical load demanded by the range. The kilowatt rating for the
range is specified on the rating plate. Seestep 8 for location of rating
plate.
Most local Building Regulationsand Codes require that all electrical
wiring be done by licensed electricians. All wiring should conform to
Local and National Electrical Codes.This range requires a single phase
three wire 120/240 or a 120/208 volt, 60 Hz,AC circuit. Wiring codes
require a separate circuit be run from the main entrance panel to the
range and that it be equipped with separate disconnect switch and
fuses, either in the main entrance panel or in a separate switch and
fuse box.
Some models are shipped direct from the factory with service cord
attached. There are no range connections necessary on these models.
Just plug into the wall outlet. On models not provided with a service
cord, connection to the power supply is necessaryin accordancewith
local codes. Provisionsfor using either conduit or a flexible power cord
are provided. When using a power supply cord, use only a supply cord
with closed loop terminals rated either 240 volts, 40 amps or 240 volts,
50 amps that is marked for use with nominal 1-3/8" (34.94 mm)
diameter connection opening and marked for ranges. A 4-conductor
cord is to be used on new branch-circuit installations (1996 NEC),
mobile homes,recreational vehicles and where local codes prohibit
grounding through the neutral conductor.A 3-wire service may be used
when permitted by local codes.When a power supply cord is used, a
cord no longer than 4 feet should be used.
Canada
This modelis shippeddirect from the factory with the servicecord
attached.Thereare no rangeconnectionsnecessary.

Advertisement

loading

This manual is also suitable for:

Jes9900baf