Set the FDX or AUTO switches on the rear panel for the duplex mode.
2.
A hub and repeater use a common collision domain for all communications and cannot support
full-duplex mode. When connecting any of the 10/100 Mbps ports on the switch to a hub, set
the port to AUTO. The switch must also be set to AUTO when connecting to any device that
does not use NWay autonegotiation to detect the operating mode. Setting the toggle switch to
AUTO will cause the port to default to half-duplex mode when connecting to a port that does
not use NWay autonegotiation.
When connecting to a PC, a server, or another switch, the duplex setting for the port must be
the same as the duplex setting on the PC, server, or other switch.
To set the 10/100 Mbps ports for the selected duplex mode:
Move the toggle switch into the down position (to AUTO) for auto-duplex mode.
The 10/100 Mbps ports will negotiate and automatically determine the duplex mode
based on the mode of the connected port. If the connected port cannot autonegotiate,
the 10/100 Mbps port will default to half-duplex. The factory setting of the duplex toggle
switches is AUTO.
Move the toggle switch into the up position (to FDX) for full-duplex mode.The duplex
switch must be set to FDX if you are connecting to legacy full-duplex 100 Mbps devices
that do not generate signals indicating duplex mode. If the duplex switch is set to AUTO
mode when connecting to legacy full-duplex 100 Mbps devices, the 10/100 Mbps ports
will default to half-duplex mode because the port does not receive the proper signal.
Set the FDX or HDX switches on the rear panel for each fiber port.
3.
The duplex mode of the fiber port must match the duplex mode of the remote port.
Connect one end of the power cord to the power outlet on the back panel of the switch,
4.
and connect the other end of the power cord to a wall receptacle.
The switch automatically selects the proper voltage in the range of 100 to 240 volts.
The Power LED lights, and the cooling fans start up after successfully completing the
self-tests. The switch is now operational.
Make sure that Link Status LEDs are illuminated for all connected ports.
5.

Verifying Installation

Verify network communications by ensuring that all the necessary connections have been made,
that all connected resources can be accessed, and that the LED indicators on the switch are
functioning properly. For additional information, refer to Chapter 5, "Troubleshooting."