Unable to send reports to a file location by using ZENworks Reporting Server
InfoView if ZENworks Reporting Server is installed on SLES 10 server
Explanation: If ZENworks Reporting Server is installed on a SLES 10 server, you might
Unable to create a new Web Intelligence document in the ZENworks Reporting
Server InfoView
Explanation: In the ZENworks Reporting Server InfoView, you might encounter an error
Possible Cause: The report panel preference for the Web Intelligence document is set to Query-
Reports data displays #incompatible when the user creates a report by using Query
HTML
Possible Cause: The report panel preference for the Web Intelligence document is set to Query-
34
ZENworks 10 Configuration Management System Reporting Reference
Source: ZENworks 10 Configuration Management SP3; System Reporting
encounter the following error message when you try to send a report to a file
location by using the ZENworks Reporting Server InfoView (from the Header
panel, click Send > To File Location):
The destination plugin required for this action is disabled.
If you require this functionality, please contact your system
administrator.
Action: None.
Source: ZENworks 10 Configuration Management SP3; System Reporting
when you click Run Query while creating a new Web Intelligence document.
HTML.
Action: Change the report panel preference of the Web Intelligence document to Java
Report Panel.
1 Launch the ZENworks Reporting Server InfoView.
2 Click Preferences.
3 Click the Web Intelligence Document tab.
4 Select Java Report Panel.
5 Click Apply > OK.
Source: ZENworks 10 Configuration Management SP3; System Reporting
HTML when creating a report.
Action: Do the following to change the report panel preference of the Web Intelligence
document to Java Report Panel:
1 Launch the ZENworks Reporting Server InfoView.
2 Click Preferences.
3 Click the Web Intelligence Document tab.
4 Select Java Report Panel.
5 Click Apply > OK.
6 Create the report again.