TABLE OF CONTENTS INTRODUCTION Safety Instructions ....................................3 Installation And Operation ..................................4 Common Parts List ....................................6 Motor Wiring Diagram ..................................7 Troubleshooting ....................................8 Warranty ......................................11 HYD1045 (05/15/2021)
SAFETY INSTRUCTIONS SAFETY SYMBOLS Pump The HV200 pumps are equipped with 200 and 230 volt single-phase and 200, 230, 460 and 575 volt three-phase with seal leak detector. HV200 This is the safety alert symbol. When you see this symbol on your Series pumps are available in high flow, standard, or high head.
INSTALLATION AND OPERATION INSTALLING PUMP IN SUMP IMPORTANT: If equipment is not properly wired and protected as recommended, Hydromatic warranty is void. Before installing pump in sump, lay it on its side and rotate impeller. Im pel ler may be slightly stuck due to fac to ry test water HEAT SENSOR AND SEAL FAILURE CONNECTIONS: so it must be broken loose with a small bar or screwdriver in If a Hydromatic control panel is used, terminal blocks are...
INSTALLATION AND OPERATION PUMP MAINTENANCE As the motors are oil filled, no lubrication or other maintenance is re quired. If the heat sensor and seal failure are hooked up properly, no attention is necessary as long as the seal failure indicator light doesn’t come on.
Page 7
COMMON PARTS LIST ITEM ENGINEERING NO. DESCRIPTION QTY. 28139B000 230 V 1 Phase Motor Assembly 28139B001 200 V 3 Phase Motor Assembly 28139B002 230/460 V 3 Phase Motor Assembly 28139B004 575 V 3 Phase Motor Assembly 28139B003 200 V 1 Phase Motor Assembly 28228B000 Impeller, HVH200, 6.25”...
MOTOR WIRING DIAGRAM WHITE BLACK WHITE BLACK ORANGE ORANGE GREEN BLUE GREEN BLUE WHITE W/ BLACK WHITE W/ BLACK STRIPE STRIPE T1-T7 T2-T8 WHITE T3-T9 HEAT SENSOR BLACK HEAT SENSOR T6-T5-T4 YELLOW YELLOW SEAL SEAL LEAK DETECTOR LEAK DETECTOR 2HP, 200V AND 230V 1PH 2HP,230V 3PH WITH WITH SEAL LEAK DECTECTOR WITH SEAL LEAK DETECTOR...
TROUBLESHOOTING CONDITION PROBABLE CAUSE Pump runs but does not pump liquid from Pump impeller may be air locked; this occasionally occurs in a new installation. Start and stop pump several times to purge air. basin. Run additional water into basin so that the pump will be submerged deeper to clear air. ...
Pentair Hydromatic will cover only the lower seal and labor thereof for all dual seal pumps. Under no circumstance will Pentair Hydromatic be responsible for the cost of fi eld labor, travel expenses, rented equipment, removal/reinstallation costs or freight expenses to and from the factory or an authorized Pentair Hydromatic service facility.
Page 12
AMERICAS CANADA pentair.com 1101 Myers Parkway 490 Pinebush Road, Ashland, Ohio 44805 Unit 4 PH: 855-274-8947 Cambridge, Ontario, Canada N1T 0A5 PH: 800-363-7867 All indicated Pentair trademarks and logos are property of Pentair. Third party registered and unregistered trademarks and logos are the property of their respective owners. Because we are continuously improving our products and services, Pentair reserves the right to change specifications without prior notice.