Download Print this page
Pentair Hydromatic HVR200 Series Installation And Service Manual

Pentair Hydromatic HVR200 Series Installation And Service Manual

Advertisement

Quick Links

INSTALLATION AND SERVICE MANUAL
GRINDER PUMPS
HYDROMATIC
NOTE! To the installer: Please make sure you provide this manual to the owner of the equip ment or to the responsible
party who maintains the system.
Part # HYD1046 | © 2018 Pentair plc | 10/04/18
ENGLISH: PAGES 2-8
Installation and Service Manual
NOTE! To the installer: Please make sure you provide
this manual to the owner of the equip ment or to the
responsible party who maintains the system.
7194 0417
Models
HVR200 SERIES

Advertisement

loading

Summary of Contents for Pentair Hydromatic HVR200 Series

  • Page 1 INSTALLATION AND SERVICE MANUAL Models GRINDER PUMPS HVR200 SERIES ENGLISH: PAGES 2-8 Installation and Service Manual NOTE! To the installer: Please make sure you provide this manual to the owner of the equip ment or to the responsible party who maintains the system.
  • Page 2 USAGE CAUTION! The HVR200 Series is a submersible wastewater grinder THE HVR200 SERIES GRINDER PUMP SHOULD NEVER pump designed specifically for individual residential and BE WORKED ON WITHOUT FIRST DISCONNECTING THE pressure sewer applications. The pumps are to be used POWER CORD.
  • Page 3: Safety Warnings

    4. Inspect rotating cutter and stationary cutter plate for wear and replace if worn. The HVR200 Series grinder pumps have a GROUND WIRE 5. Make sure pocket in volute is clean and reinstall that is connected to a screw in the metal motor housing.
  • Page 4 9. Replace retaining washer and screw in the end of the 5. Slide motor housing up far enough to expose the shaft. Be sure screw is tight. A screwdriver can be capacitors and to be able to lay the housing down. used to hold the shaft in place by wedging it between 6.
  • Page 5: Troubleshooting Guide

    TROUBLESHOOTING GUIDE Pump does not run or hum. A. Line circuit breaker may be off; J. Pump head may be too high. See A, B, C, D, E or F. or fuse, if used, may be blown Horizontal distance does not or loose.
  • Page 6: Common Parts List

    MOTOR END PARTS COMMON PARTS LIST For use with product built with Marathon motor. ® Engineering Item Description 28165B000 Motor Assembly - All Models 28228B001 Impeller, 5.313" O.D. - HVRS200 models 28228B002 Impeller, 6.00" O.D. - HVRH200 models 28228B003 Impeller, 4.50" O.D. - HVRF200 models 25338B001 Power Cord, 14-3, 20' 28132B000...
  • Page 7 THIS PAGE INTENTIONALLY LEFT BLANK...
  • Page 8 During the warranty period and subject to the conditions set forth, Pentair Hydromatic, at its discretion, will repair or replace to the original user, the parts that prove defective in materials and workmanship. Pentair Hydromatic reserves the right to change or improve its products or any portions thereof without being obligated to provide such a change or improvement for prior sold and/or shipped units.