SMC Networks D-B53 Series Instruction Manual

Hide thumbs Also See for D-B53 Series:

Advertisement

D#ZZ-TF223-002EN
Instruction Manual
Reed Auto switch - Band mounting
Series D-B53 / D-B54 / D-B64 / D-B59W
The intended use of the auto switch is to detect and control the position
of an actuator using magnetic detection.
1 Safety Instructions
These safety instructions are intended to prevent hazardous situations
and/or equipment damage. These instructions indicate the level of
potential hazard with the labels of "Caution," "Warning" or "Danger."
They are all important notes for safety and must be followed in addition
to International Standards (ISO/IEC)
*1)
ISO 4414: Pneumatic fluid power - General rules relating to systems.
ISO 4413: Hydraulic fluid power - General rules relating to systems.
IEC 60204-1: Safety of machinery - Electrical equipment of machines.
(Part 1: General requirements)
ISO 10218-1: Manipulating industrial robots -Safety. etc.
• Refer to product catalogue, Operation Manual and Handling
Precautions for SMC Products for additional information.
• Keep this manual in a safe place for future reference.
Caution
Warning
Danger
• Always ensure compliance with relevant safety laws and
standards.
• All work must be carried out in a safe manner by a qualified person in
compliance with applicable national regulations.
• This product is class A equipment intended for use in an industrial
environment. There may be potential difficulties in ensuring
electromagnetic compatibility in other environments due to conducted
or radiated disturbances.
• Special products (-****) might have specifications different from those
shown in the Specifications section. Contact SMC for specific
drawings.
Caution indicates a hazard with a low level of risk which, if
not avoided, could result in minor or moderate injury.
Warning indicates a hazard with a medium level of risk
which, if not avoided, could result in death or serious injury.
Danger indicates a hazard with a high level of risk which, if
not avoided, will result in death or serious injury.
Warning
Warning
ORIGINAL INSTRUCTIONS
*1)
, and other safety regulations.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the D-B53 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for SMC Networks D-B53 Series

  • Page 1 D#ZZ-TF223-002EN ORIGINAL INSTRUCTIONS Instruction Manual Reed Auto switch - Band mounting Series D-B53 / D-B54 / D-B64 / D-B59W The intended use of the auto switch is to detect and control the position of an actuator using magnetic detection. 1 Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage.
  • Page 2: Specifications

    2 Specifications 2.1 Specifications Model D-B53 D-B54 D-B64 D-B59W Wiring style 2 wire Application Relay, PLC Maximum Load 24 V voltage AC/DC 5 to Maximum Load 5 to 50 5 to 5 to 12.5 5 to 40 12.5 current (or range) 50 mA 25 mA Contact protection...
  • Page 3: Installation

    4 Installation 4.1 Installation Warning • Do not install the product unless the safety instructions have been read and understood. 4.2 Design and Selection 1) Confirm the specifications. Read the specifications carefully and use the product correctly. The product may be damaged or malfunction if it is used outside of the specification range.
  • Page 4 4 Installation (continued) 4) Mount a switch at the centre of the operating range. Adjust the auto switch mounting position so that the piston stops at the centre of the operating range (the range in which the switch is ON). The auto switch Red LED will turn ON. For the 2 colour type auto switch (D-B59W) the Green LED turns ON to indicate the optimum position.
  • Page 5 D#ZZ-TF223-002EN 4 Installation (continued) 4.5 Wiring 1) Avoid repeatedly bending or stressing lead wires. Broken lead wires can result from wiring layouts which repeatedly apply bending stress or stretching force to the lead wires. 2) Be sure to connect the load before power is applied. If the power is turned ON when an auto switch is not connected to a load, the switch will be instantly damaged due to excess current.
  • Page 6: How To Order

    4 Installation (continued) 4.6 Environment Warning • Do not use in an environment where oil, corrosive gases, chemicals, salt water or steam are present. • Do not install in a location subject to vibration or impact in excess of the product specifications. •...
  • Page 7 8 Troubleshooting When detection failure occurs check the switch according to the chart Problem Stays ON Stays OFF Output Normal, (sometimes stays ON) (sometimes stays OFF) Lamp does not light up Lamp lights up Lamp does not light up Check operating Check operating environment, environment, Load specification and Wire length...