Pool Spa - AMX CAFE DUET STANDARD NETLINX API (SNAPI) COMPONENTS AND LISTENERS Instruction Manual

Standard netlinx api (snapi) r 1.8.0 components/listeners
Table of Contents

Advertisement

Pool Spa

Component
Name: Pool Spa
Interface: IPoolSpaComponent
Component Functions:
Name:
Channel:
Level: Command:
cyclePoolHeatState()
123
cycleSpaHeatState()
124
cycleSpaJets()
125
decrementPoolSetpoint()
153
decrementSpaSetpoint()
155
getPoolSpaTempera-
tureScale()
incrementPoolSetpoint()
152
incrementSpaSetpoint()
154
isPoolSpaAuxOn(aux)
setPoolHeat-
175
State(HEATER)
setPoolHeatState(OFF)
174
setPoolHeat-
176
State(SOLAR)
setPoolHeat-
177
State(SOLAR_PREFER
RED)
setPoolLightOn(state)
172
setPoolPumpOn(state)
170
setPoolSetpoint(nTem-
perature)
setPool-
SpaAuxOn(aux,state)
setPoolSpaTempera-
tureScale(ts)
setSpaBlowerOn(state)
186
setSpaHeat-
179
State(HEATER)
setSpaHeatState(OFF)
178
Standard NetLinx API (SNAPI) R 1.8.0
IPoolSpaComponent
?POOLSCALE
?POOLAUX-<aux number>
39
POOLAUX-<aux number>,<state>
POOLSCALE-<ts>
Constant:
Notes:
POOL_HEAT
Momentary Function Channel: Cycle Pool heat state when channel is activated
SPA_HEAT
Momentary Function Channel: Cycle Spa heat state when channel is activated
SPA_JETS
Momentary Function Channel: Cycle Spa jets when channel is activated
POOL_HEAT_DN
Momentary Function Channel: Pool setpoint is decremented when channel is activated
SPA_HEAT_DN
Momentary Function Channel: Spa setpoint is decremented when channel is activated
Query for the Pool/Spa temperature scale, responds with POOLSCALE-<scale> where
<scale> is FAHRENHEIT, CELSIUS
POOL_HEAT_UP
Momentary Function Channel: Pool setpoint is incremented when channel is activated
SPA_HEAT_UP
Momentary Function Channel: Spa setpoint is incremented when channel is activated
Query for Pool/Spa Aux state, responds with POOLAUX-<aux number>,<state> where
<state> is 0 (false) or 1 (true)
POOL_HEATER
Momentary Function Channel: Set Pool heat state to heater
POOL_HEAT_OFF
Momentary Function Channel: Set Pool heat state to off
POOL_SOLAR
Momentary Function Channel: Set Pool heat state to solar
POOL_SOLAR_PREF
Momentary Function Channel: Set Pool heat state to solar preferred
POOL_LIGHT_ON
Discrete Function Channel: Pool light is on while channel is active
POOL_PUMP_ON
Discrete Function Channel: Pool pump is on while channel is active
POOL_HEAT_LVL
Set Pool setpoint, value is in degrees C or F depending on temperature scale
Set Pool/Spa Aux state where <aux number> is the number of the aux relay 1 to x
where x is the maximum supported aux relay and <state> is 1 (on) or 0 (off) (see spe-
cific module documentation)
Set the Pool/Spa temperature scale, where <ts> is FAHRENHEIT, CELSIUS
SPA_BLOWER_ON
Discrete Function Channel: Spa blower is on while channel is active
SPA_HEATER
Momentary Function Channel: Set Spa heat state to heater
SPA_HEAT_OFF
Momentary Function Channel: Set Spa heat state to off
97