AMX CAFE DUET STANDARD NETLINX API (SNAPI) COMPONENTS AND LISTENERS Instruction Manual page 105

Standard netlinx api (snapi) r 1.8.0 components/listeners
Table of Contents

Advertisement

Listener Functions: (Cont.)
Name:
Channel:
Level: Command:
processPoolSpaAuxOn-
Event
processPoolSpaOut-
34
doorTemperatureEvent
processPoolSpaTemper-
atureScaleEvent
processPoolTemperatu-
41
reEvent
processSpaBlowerOn-
186
Event
processSpaHeat-
179
StateEvent
processSpaHeat-
178
StateEvent
processSpaHeat-
180
StateEvent
processSpaHeat-
181
StateEvent
processSpaHeatSta-
189
tusEvent
processSpaHeatSta-
190
tusEvent
processSpaJetsEvent
185
processSpaJetsEvent
183
processSpaJetsEvent
184
processSpaJetsEvent
182
processSpaLightOn-
173
Event
processSpaPumpOn-
171
Event
processSpaSet-
40
pointEvent
processSpaTemperatu-
42
reEvent
Standard NetLinx API (SNAPI) R 1.8.0
Constant:
POOLAUX-<aux number>,<state>
OUTDOOR_TEMP_LVL
POOLSCALE-<scale>
POOL_TEMP_LVL
SPA_BLOWER_FB
SPA_HEATER_FB
SPA_HEAT_OFF_FB
SPA_SOLAR_FB
SPA_SOLAR_PREF_FB
SPA_HEATING
SPA_HEATING_SOLAR
SPA_JETS_HI_FB
SPA_JETS_LO_FB
SPA_JETS_MED_FB
SPA_JETS_OFF_FB
SPA_LIGHT_FB
SPA_PUMP_FB
SPA_HEAT_LVL
SPA_TEMP_LVL
Notes:
Pool/Spa Aux state changed where <aux number> is the number of the aux relay 1 to x
where x is the maximum supported aux relay and <state> is 1 (on) or 0 (off) (see spe-
cific module documentation)
Outdoor air temperature changed, value is in degrees C or F depending on temperature
scale
Pool temperature scale changed, <scale> is FAHRENHEIT,CELSIUS
Pool temperature changed, value is in degrees C or F depending on temperature scale
Feedback Channel: Spa blower is on while channel is active
Feedback Channel: Spa heater set to heat state, see state chart
Feedback Channel: Spa heater set to off state, see state chart
Feedback Channel: Spa heater set to solar state, see state chart
Feedback Channel: Spa heater set to solar preferred state, see state chart
Feedback Channel: Spa heater status is heater, see state chart
Feedback Channel: Spa heater status is solar, see state chart
Feedback Channel: Spa jets state is high, see state chart
Feedback Channel: Spa jets state is low, see state chart
Feedback Channel: Spa jets state is medium, see state chart
Feedback Channel: Spa jets state is off, see state chart
Feedback Channel: Spa light is on while channel is active
Feedback Channel: Spa pump is on while channel is active
Spa setpoint changed, value is in degrees C or F depending on temperature scale
Spa temperature changed, value is in degrees C or F depending on temperature scale
99

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CAFE DUET STANDARD NETLINX API (SNAPI) COMPONENTS AND LISTENERS and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

This manual is also suitable for:

Cafe duet

Table of Contents