Lamp - AMX CAFE DUET STANDARD NETLINX API (SNAPI) COMPONENTS AND LISTENERS Instruction Manual

Standard netlinx api (snapi) r 1.8.0 components/listeners
Table of Contents

Advertisement

Lamp

Component
Name: Lamp
Interface: ILampComponent
Component Functions:
Name:
Channel:
Level: Command:
cycleLampPower()
9
getCoolDownTime()
getLampTime()
getWarmUpTime()
setCoolDownTime(secs)
setCounterNotifica-
tionOn(state)
setLampPower(OFF)
28
setLampPower(ON)
27
setLampPower(ps)
255
setLampTime(hours)
setWarmUpTime(secs)
Listener
Name: Lamp Listener
Interface: ILampComponentListener
Listener Functions:
Name:
Channel:
Level: Command:
processCoolDownCoun-
terEvent
processLampPower-
254
Event
processLampPower-
255
Event
processLampPower-
253
Event
processLampTimeEvent
processWarmUpCoun-
terEvent
Standard NetLinx API (SNAPI) R 1.8.0
ILampComponent
Constant:
POWER
?COOLDOWN
?LAMPTIME
?WARMUP
COOLDOWN-<time>
COUNTERNOTIFY-<state>
PWR_OFF
PWR_ON
POWER_ON
LAMPTIME-<time>
WARMUP-<time>
ILampComponentListener
Constant:
COOLING-<time>
LAMP_COOLING_FB
LAMP_POWER_FB
LAMP_WARMING_FB
LAMPTIME-<time>
WARMING-<time>
Notes:
Momentary Function Channel: Cycle lamp power when channel is activated
Query for cool down time, responds with COOLDOWN-<time> where <time> is in sec-
onds
Query for lamp time, responds with LAMPTIME-<time> where <time> is in hours
Query for warm up time, responds with WARMUP-<time> where <time> is in seconds
Set cool down time where <time> is in seconds
Turn counter notification on or off, where <state> is 1 or 0
Momentary Function Channel: Lamp power is turned off when channel is activated
Momentary Function Channel: Lamp power is turned on when channel is activated
Discrete Function Channel: Lamp power is on while channel is active
Set lamp time where <time> is in hours
Set warm up time where <time> is in seconds
Notes:
Cool down counter time, <time> is seconds remaining
Feedback Channel: Indicates Lamp is cooling and cannot accept commands
Feedback Channel: Indicates lamp is ON
Feedback Channel: Indicates Lamp is warming and cannot accept commands
Lamp time, <time> is elapsed hours
Warm up counter time, <time> is seconds remaining