DeVilbiss MGP-FAC100-1 Owner's Manual

Devillbiss air power company air compressor owners manual

Advertisement

Quick Links

*A circuit breaker is preferred. Use only a fuse or circuit breaker that is the same
rating as the branch circuit the air compressor is operated on. If the air compressor
is connected to a circuit protected by fuses, use quick acting fuses.
SAFETY GUIDELINES - DEFINITIONS
This manual contains information
that is important for you to know
and understand. This information
relates to protecting YOUR
SAFETY and PREVENTING
EQUIPMENT PROBLEMS. To
help you recognize this informa-
tion, we use symbols to the right.
Please read the manual and pay
attention to these sections.
MGP-FAC100-1 6/2/97
OWNERS MANUAL FOR
PERMANENTLY LUBRICATED
AIR COMPRESSOR
MODEL NO.
FAC100-1
(For Home Use Only)

SPECIFICATION CHART

Model No.
Horsepower
SCFM @ 40 psig
SCFM @ 90 psig
Bore
Stroke
Voltage-Single Phase
Minimum Branch Circuit Requirement
*Fuse Type
Amperage at Max Pressure
URGENT SAFETY INFORMATION - A HAZ-
ARD THAT WILL CAUSE SERIOUS INJURY
OR LOSS OF LIFE.
IMPORTANT SAFETY INFORMATION - A
HAZARD THAT MIGHT CAUSE SERIOUS
INJURY OR LOSS OF LIFE.
FAC100-1
DeVilbiss Air Power Company • 213 Industrial Dr. • Jackson, TN 38301-9615
Information for preventing damage to
equipment.
Information that you should pay special
attention to.

Advertisement

Table of Contents
loading

Summary of Contents for DeVilbiss MGP-FAC100-1

  • Page 1: Specification Chart

    *A circuit breaker is preferred. Use only a fuse or circuit breaker that is the same rating as the branch circuit the air compressor is operated on. If the air compressor is connected to a circuit protected by fuses, use quick acting fuses.
  • Page 2: Table Of Contents

    WARNING CHART ... 4-5 GLOSSARY ... DUTY CYCLE ... DESCRIPTION OF OPERATION ... INSTALLATION AND BREAK-IN PROCEDURES ... Location of Air Compressor ... TABLE OF CONTENTS Page Extension Cords ... 6 Grounding Instructions ... 6-7 Air Hose ... OPERATING PROCEDURES ...
  • Page 3: Warranty Statement

    45 days from the date of purchase. An air compressor that pumps air more than 50% during a one hour period is considered misuse because the air compressor is undersized for the required air demand. Maximum compressor pumping time per hour is 30 minutes.
  • Page 4: Warning Chart

    OUS OVERHEATING AND COULD CAUSE FIRE. UNATTENDED OPERATION OF THIS PROD- UCT COULD RESULT IN PERSONAL INJURY OR PROPERTY DAMAGE. YOUR AIR COMPRESSOR IS POWERED BY RISK OF ELECTRICITY. ELECTRICAL SHOCK CALLY POWERED DEVICE, IF IT IS NOT USED PROPERLY SHOCK.
  • Page 5: Glossary

    All DeVilbiss Air Power manufactured air compressors should be operated on not more than a 50% duty cycle. This means an air compressor that pumps more than 50% of one hour, is considered misuse, because the air compressor is undersized for the required air demand.
  • Page 6: Description Of Operation

    Location of the Air Compressor Your compressor comes to you completely assembled and ready for use. Operate the air compressor in a dry, clean, cool and well ventilated area. The air compressor pump and case are designed to allow for proper cooling.
  • Page 7: Air Hose

    120 Volt Models 120 Volts, 15 Amps OPERATING PROCEDURES 1. Before plugging in the air compressor, set the adjust- able pressure valve to "10" PSI. Make sure the "ON/ OFF" switch is in the "OFF" position. 2. Connect the air tool or accessory to the air hose.
  • Page 8: Storage

    10 P.S.I. STORAGE 3. Protect the electrical cord and air hose from damage by winding them loosely around the air compressor. 4. Store the air compressor in a clean and dry location.
  • Page 9: Air Compressor

    AIR COMPRESSOR DIAGRAM...
  • Page 10: Parts List

    PART NUMBER ----- CAC-1196 CAC-1212 CAC-1199 CAC-4323 SSG-8169 CAC-1194-1 ----- ----- ----- CAC-1342 CAC-1213 AC-0470 SSS-16 CAC-1211 AC-0475 AC-0471 ----- CAC-1206 CAC-4324 ----- KK-4930 Isolator Kit includes items 3, 4, 6, 13, 16. KK-4929 Fastener Kit includes items 1, 9, 22, 25. KK-4926 Connecting Rod Kit includes items 8, 10.
  • Page 11: Troubleshooting Guide

    TROUBLESHOOTING GUIDE VOLTAGE SOURCES, MOVING PARTS OR COMPRESSED AIR SOURCES ARE EXPOSED WHEN REPAIRING THE COMPRESSOR. PERSONAL INJURY CAN OCCUR. UNPLUG THE COMPRESSOR BEFORE ATTEMPTING ANY REPAIRS. PROBLEM CAUSE Air Leaks Hose fitting loose. Compressor is not delivering Prolonged excessive use of air. enough air.
  • Page 12 PERMANENTLY LUBRICATED AIR COMPRESSOR Call our Toll Free Number 1-800-888-2468, Ext 2, then 1, to obtain the location of the nearest Authorized Service Center for ordering repair parts and for warranty repairs. When ordering repair parts from your local Authorized Service Center, always give the following information: •...

This manual is also suitable for:

Fac100-1

Table of Contents