PERMANENTLY LUBRICATED
Model No.
Horsepower
SCFM @ 40 psig
SCFM @ 90 psig
Displacement CFM
Bore
Stroke
Voltage-Single Phase
Minimum Branch Circuit Requirement
*Fuse Type
Tank Size
*A circuit breaker is preferred. Use only a fuse or circuit breaker that is the same rating
as the branch circuit the air compressor is operated on. If the air compressor is
connected to a circuit protected by fuses, use quick acting fuses.
This unit is a continuous run unit. It does not start and stop automatically.
NOTE:
For identification of Repair Parts,
see separate Parts List Manual.
MGP-102D-2 2/1/94
OWNERS MANUAL FOR

AIR COMPRESSOR

MODEL NO. 102D-1
(For Home Use Only)

SPECIFICATION CHART

IMPORTANT:
Read and Retain the Safety
Guidelines and All Instructions
Carefully Before Operating.
DeVilbiss Air Power Company, 213 Industrial Dr., Jackson, TN 38301-9615
102D-1
C102D-1
3/4
---
3.0
3.0
2.2
2.2
4.0
4.0
1 3/4"
1 3/4"
1 1/4"
1 1/4"
110-120
110-120
15 AMPS
15 AMPS
Quick Acting
Quick Acting
2 Gallon
2 Gallon
WARRANTY:
For Warranty Information
see page 3 of this manual.

Advertisement

Table of Contents
loading

Summary of Contents for DeVilbiss 102D-1

  • Page 1: Air Compressor

    *A circuit breaker is preferred. Use only a fuse or circuit breaker that is the same rating as the branch circuit the air compressor is operated on. If the air compressor is connected to a circuit protected by fuses, use quick acting fuses.
  • Page 2: Table Of Contents

    Simply call our toll free number and talk with our Service Representative. OUR OFFICE HOURS ARE FROM MONDAY THROUGH FRIDAY CALL TOLL FREE 1-800-888-2468, Ext. 2 TABLE OF CONTENTS Page Location of Air Compressor ... Extension Cords ... Grounding Instructions ... Air Hose ... OPERATING PROCEDURES ... TROUBLESHOOTING GUIDE ...
  • Page 3: Limited Warranty

    An air compressor that pumps air more than 50% during a one hour period is considered misuse because demand. Maximum compressor pumping time per hour is...
  • Page 4: Safety Guidelines

    On tank mounted units, avoid prolonged contact with the pump to tank plumbing. The air compressor must only be used in well ventilated areas, free of gasoline or solvent vapors. Do not operate the compressor while you are carrying it, or in the spray area.
  • Page 5: Glossary

    All DeVilbiss Air Power manufactured air compressors should be operated on not more than a 50% duty cycle. This means an air compressor that pumps more than 50% of one hour, is considered misuse, because the air compressor is undersized for the required air demand. Maximum compressor pumping time per hour is 30 minutes.
  • Page 6: Description Of Operation

    Location of the Air Compressor Your compressor comes to you completely assembled and ready for use. Operate the air compressor in a dry, clean, cool and well ventilated area. The air compressor pump and case are designed to allow for proper cooling.
  • Page 7: Air Hose

    120 Volts, 15 Amps OPERATING PROCEDURES 1. Before plugging in the air compressor, set the adjust- able pressure valve to "10" PSI. Make sure the "ON/ OFF" switch is in the "OFF" position. 2. Connect the air tool or accessory to the air hose.
  • Page 8: Troubleshooting Guide

    TROUBLESHOOTING GUIDE VOLTAGE SOURCES, MOVING PARTS OR COMPRESSED AIR SOURCES ARE EXPOSED WHEN REPAIRING THE COMPRESSOR. PERSONAL INJURY CAN OCCUR. UNPLUG THE COMPRESSOR BEFORE ATTEMPTING ANY REPAIRS. PROBLEM CAUSE Air Leaks Hose fitting loose. Compressor is not delivering Prolonged excessive use of air. enough air.
  • Page 9: Air Compressor Diagram

    Air Compressor Diagram Slide #19 over #7 as shown. Make sure that no part of #7 tube touches #21 or #14 shroud when assembled.
  • Page 10: Parts List

    Screw 3/8-16 x 1/25 LG hex socket flat head (torque to 350 in/lb) Cylinder Sleeve Endbell Assembly Timing Belt Pump Isolator (5 required) Shroud (right) for 102D-1 Shroud (right) for C102D-1 Switch Tank Isolator (4 required) Motor Baffle (right) Motor Baffle (left)
  • Page 11: Compressor Pump Diagram

    Compressor Pump Diagram...
  • Page 12 H-2099 KK-4949 Isolator Kit includes items 3, 4, 6, 13, 16, 34, 35, 27 Parts List DESCRIPTION Clamp(2 used) Pressure Valve Assembly for 102D-1 Pressure Valve Assembly for C102D-1 Ground Screw Male Connector Screw (tank retention) (as required) Pipe Cross...
  • Page 13 Service Notes...
  • Page 14 Service Notes...
  • Page 15 Service Notes...
  • Page 16 OWNERS MANUAL FOR PERMANENTLY LUBRICATED AIR COMPRESSOR MODEL NOS. 102D-1 (For Home Use Only) An "Authorized Warranty Service Center Directory" is included with your unit. When ordering repair parts from your local Authorized Service Center, always give the following information: •...

This manual is also suitable for:

C102d-1Mgp-102d-2Ir102d-caIr102d

Table of Contents