SIGLENT SHS820 User Manual

SIGLENT SHS820 User Manual

Handheld digital oscilloscope

Advertisement

Quick Links

User Manual
SHS800 Series Handheld Digital Oscilloscope
UM03008-E05A
SIGLENT TECHNOLOGIES CO,.LTD

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SHS820 and is the answer not in the manual?

Questions and answers

Summarization of Contents

Chapter 6 Service and Support
Maintain Summary and Warranty
Details product warranty, service period, and maintenance procedures.
Contact SIGLENT Support
Provides SIGLENT's official contact information for service inquiries.
Chapter 1 Accidence
Chapter Overview: Accidence
Provides an overview of the chapter's content, including front panel understanding and function check.
Front Panel and User Interface
Details the SHS800's front panel functions for operation and familiarity.
Chapter 2 Using the Scope
Chapter Overview: Using the Scope
Introduces scope functions with basic examples for menus and operations.
Menu and Control Buttons
Explains the functions of the SHS800's menu and control buttons for effective operation.
Display System
Display Menu Options (Page 1)
Covers display type, persistence, intensity, brightness, and next page.
Display Menu Options (Page 2)
Details format, screen mode, grid settings, and menu display time.
Math Waveform Operations
Math Operation Menu
Details options for waveform math operations like addition, subtraction, and multiplication.
Waveform Math Application Example
Step-by-step guide for performing waveform addition using the math function.
Horizontal System Controls
Horizontal System Menu
Provides options for horizontal system settings like delay scan and memory depth.
Delay Scan and Memory Depth
Details how to use delay scan for zoom analysis and memory depth settings.
Reference Waveform Function
Reference Waveform Menu
Explains how to save, recall, and display reference waveforms.
Reference Waveform Example
Step-by-step guide for saving and displaying a reference waveform.
Cursor and Measurement System
Manual Cursor Measurement
Details manual cursor mode for measuring voltage and time parameters.
Manual Cursor Menu Options
Covers cursor mode, type, source, and position adjustment.
Parameter Measurement
Automatic Measure Example
Step-by-step guide for using automatic measurement features.
Trigger System
Edge Trigger
Details edge trigger types, source, slope, mode, and settings.
Pulse Trigger
Explains pulse trigger conditions, width settings, and modes.
Chapter 4 Save and Recall System
Saving Setups
Details saving instrument setups to internal memory or USB flash drive.
Saving Waveforms and Pictures
Explains saving waveform data and interface images to device or USB.
Chapter 5 Utility System
Utility System Menu Options 1
Covers system status, sound, language, and counter settings.
Utility System Menu Options 2
Details self-calibration, screen/keyboard tests, and USB device setup.
Self Calibration and Print Settings
Self Calibration Procedure
Guides on calibrating the SHS800 for accurate measurements.
Print Setting Options
Details print settings like ink saver, layout, and paper size for PictBridge printers.
Waveform Recording
Waveform Record Menu
Covers recording, replaying, and setting parameters for waveform recording.
Waveform Recorder Saving
Details options for starting, replaying, copying, and saving waveforms.
Chapter 4 Oscilloscope Trend Plot
Scope Trend Plot Interface
Illustrates the user interface for scope trend plot with key elements.
Scope Trend Plot Menu Options
Details trend plot functions like restart, parameter selection, and run/stop.
Chapter 4 Multimeter Trend Plot
Multimeter Trend Plot Interface
Shows the user interface for multimeter trend plot with key components.
Multimeter Trend Plot Menu 1
Details trend plot functions like restart, sampling rate, and record mode.
Chapter 5 Prompting and Troubleshooting
System Prompting Messages
Explains various system messages and their meanings for user guidance.
Troubleshooting Common Issues
Troubleshooting: No Signal
Steps to resolve issues when no signal wave appears on the screen.
Troubleshooting: Incorrect Voltage
Guides on resolving voltage readings that are 10x higher/lower than expected.
Troubleshooting: Unsteady Waveform
Steps to fix unsteady waveforms by checking trigger settings and coupling.
Troubleshooting: No Display
Guides to resolve issues when the screen shows no display after pressing RUN/STOP.
Troubleshooting: Ladder Waveform
Explains normal causes for ladder waveforms and how to improve display.
Troubleshooting: Incorrect Measurements
Steps to address incorrect multimeter measurements and calibration checks.
Troubleshooting: Other Issues
Advice on contacting SIGLENT service for unresolved issues and warranty.
Chapter 6 Service and Support
Maintenance Summary and Warranty
Details product warranty, service period, and maintenance procedures.
Contact SIGLENT Support
Provides SIGLENT's official contact information for service inquiries.
Appendix C Daily Maintenance and Cleaning
Daily Maintenance Precautions
Guidelines for storing and maintaining the SHS800 to prevent damage.
Instrument Cleaning Procedures
Steps for safely cleaning the instrument and probes using appropriate materials.

Table of Contents