SIGLENT SDS2000 Series Quick Start Manual

SIGLENT SDS2000 Series Quick Start Manual

Digital oscilloscope

Advertisement

Quick Links

Quick Start

SDS2000 Series
Digital Oscilloscope
QS01020-E02A

Advertisement

loading
Need help?

Need help?

Do you have a question about the SDS2000 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for SIGLENT SDS2000 Series

  • Page 1: Quick Start

    Quick Start SDS2000 Series Digital Oscilloscope QS01020-E02A...
  • Page 2 Ground the Instrument Keep Well Ventilation The instrument is grounded through the protective earth Note: SIGLENT is the registered trademark of SIGLENT TECHNOLOGIES CO., LTD. inadequate ventilation may cause increasing of conductor of the power line. To avoid electric shock,...
  • Page 3: Table Of Contents

    SIGLENT SIGLENT Safety Terms and Symbols General Care and Cleaning Contents Care Terms on the product. These terms may appear on the product: Do not store or leave the instrument in direct sunshine for long periods of time. General Safety Summary...
  • Page 4: General Inspection

    The consigner or carrier will be responsible for damages to the instrument resulting from shipment. SIGLENT would not provide free maintenance or replacement. 2. Inspect the instrument If there are instruments found damaged, defective or...
  • Page 5: Adjust The Supporting Legs

    Connect the Probe 3. Use the probe to connect the CH1 Input Terminal and the Compensation Signal Output Terminal on the front panel. SIGLENT provides passive probe for the SDS2000 series oscilloscope. Please refer to corresponding Probe User 4. Press Manual for detailed technical information.
  • Page 6: Function Inspection

    SIGLENT SIGLENT Probe Compensation The Front Panel 6. Test the other channels in the same method. If the actual square waveforms does not match that in the figure above, please perform “Probe Compensation”. You should properly compensate the probe at first use of it.
  • Page 7: The Rear Panel

    SIGLENT SIGLENT The Rear Panel Front Panel Function Brief Trigger Control Horizontal Control 1. Handle Pull up the handle vertically for easy carrying; press it down if you do not :Press need the handle. the button to open 2. EXT TRIG Connector waveform display mode menu.
  • Page 8 SIGLENT SIGLENT Interval Trigger Pattern Trigger Runt Trigger I2C Trigger The time interval from the rising edge (or falling edge) of Identify a trigger condition by looking for a specified Runt trigger includes positive runt trigger and negative After setting the serial 1 or 2 to I2C type in trigger menu, input signal passes through the trigger level to the next pattern.
  • Page 9: Vertical Control

    SIGLENT SIGLENT Vertical Control SPI Trigger :Press the button to set to Normal trigger mode. After setting the serial trigger to SPI type in trigger menu, Vertical Scale :Modify the vertical scale of current you can select to trigger on MISO data or MOSI data.
  • Page 10 SIGLENT SIGLENT Run Control Decoding for I2C signal of 7 address is described in :Press the button to enable the reference the following figure. waveform function, thus to compare the current waveform Press the button to reset the oscilloscope to its with the reference waveform to decide circuit failures.
  • Page 11 SIGLENT SIGLENT Universal Knob Function Menus :Press the button to enable HELP function,and :Press the button to enter the sample setting then press down any menu to display corresponding help menu to set the acquisition mode (Normal/Peak Detect/ Average/High Res), dot inserting mode and memory information.To display the submenus help information of...
  • Page 12 7. USB Device Interface Mark 1. Product Logo Indicate the current set of USB Device Interface. If the 11. Channel Setting SIGLENT is the registered icon displays , the interface is set to USBTMC, Probe Attenuation Factor Display currently selected trademark of our company.
  • Page 13 (5)Restart the instrument and then insert the USB to check it. signalconnecting cord. correct trigger type can the waveform stably displays. (6)If it is still in abnormal use, please contact with SIGLENT. (4)Change the setting of trigger holdoff. SDS2000 Quick Start...