Download Print this page
Unitronics UID-0016R User Manual

Unitronics UID-0016R User Manual

Uni-i/o modules

Advertisement

Quick Links

Uni-I/O™ Modules
Uni-I/O™ is a family of Input/Output modules that are compatible with the UniStream™ control platform.
This guide provides basic installation information for UID-0808R, UID-0808T, UID-0808THS, UID-1600,
UID-0016R, and UID-0016T modules.
Technical specifications may be downloaded from the Unitronics website.
The UniStream™ platform comprises
CPU controllers, HMI panels, and local
I/O modules
that snap together to form an
all-in-one Programmable Logic
Controller (PLC).
Install Uni-I/O™ modules:
▪ Onto the back of any UniStream™ HMI
Panel comprising a CPU-for-Panel.
Onto a DIN-rail, using a
Local Expansion Kit.
The maximum number of Uni-I/O™ modules that can be connected to a single CPU controller is limited.
For details, please refer to the specification sheets of the UniStream™ CPU or any of the relevant Local
Expansion Kits.
Before You Begin
Before installing the device, the installer must:
▪ Read and understand this document.
▪ Verify the Kit Contents.
Installation option requirements
If you are installing a Uni-I/O™ module onto:
▪ A UniStream™ HMI Panel; the Panel must comprise a CPU-for-Panel, installed according to the CPU-for-
Panel installation guide.
A DIN-rail; you must use a Local Expansion Kit, available by separate order, to integrate the Uni-I/O™
modules on the DIN-rail into a UniStream™ control system.
Alert Symbols and General Restrictions
When any of the following symbols appear, read the associated information carefully.
Symbol
Meaning
Danger
Warning
Caution
Caution
▪ All examples and diagrams are intended to aid understanding, and do not guarantee operation. Unitronics
accepts no responsibility for actual use of this product based on these examples.
▪ Please dispose of this product according to local and national standards and regulations.
▪ This product should be installed only by qualified personnel.
▪ Failure to comply with appropriate safety guidelines can cause severe injury or property damage.
▪ Do not attempt to use this device with parameters that exceed permissible levels.
▪ Do not connect/disconnect the device when power is on.
Unitronics
User Guide
UID-0808R, UID-0808T, UID-0808THS
UID-1600, UID-0016R, UID-0016T
The identified danger causes physical and property damage.
The identified danger could cause physical and property damage.
Description
Use caution.
1

Advertisement

loading
Need help?

Need help?

Do you have a question about the UID-0016R and is the answer not in the manual?

Questions and answers

Summarization of Contents

Uni-I/O Modules Overview and Installation
Introduction to Uni-I/O Modules
Introduces Uni-I/O modules as compatible Input/Output modules for the UniStream control platform.
Installation Options and Requirements
Details installation methods (HMI Panel, DIN-rail) and pre-installation checks.
Safety Alerts and General Restrictions
Explains alert symbols (Danger, Warning, Caution) and general safety guidelines for safe operation.
Environmental and Physical Module Details
Environmental Installation Considerations
Specifies required ventilation space and environmental conditions to avoid during installation.
Uni-I/O Module Kit Contents and Diagram
Lists the components included in the kit and provides a diagram of the module's parts.
Module Connectivity and Handling Procedures
I/O Bus Connector Descriptions
Details the left and right I/O bus connectors, their function, and connection possibilities.
General Safety and ESD Precautions
Emphasizes turning off power and using ESD precautions before handling or connecting modules.
Installing Module onto HMI Panel
Step-by-step guide for mounting Uni-I/O modules onto a UniStream HMI Panel.
Removing Module from System
Step-by-step guide for safely detaching Uni-I/O modules from the system.
DIN-rail Installation and Compliance Information
Installing Uni-I/O Modules onto DIN-rail
Instructions for mounting modules on a DIN-rail using a Local Expansion Kit.
Module Numbering Procedure
Explains how to use provided stickers to number the modules for easy reference.
UL Compliance for Hazardous Locations
Details UL listing and suitability for Class I, Division 2, Groups A, B, C and D locations.
Wiring Guidelines and Procedures
General Wiring Guidelines for Interference Prevention
Provides essential rules for proper wiring to avoid interference and electrical damage.
Wiring Procedure Steps with Crimp Terminals
Step-by-step instructions for using crimp terminals and wiring modules correctly.
Uni-I/O Module Connection Points Reference
Refers to diagrams for I/O connection points arranged in groups for wiring.
Module Specific Input/Output Diagrams
UID-0808R and UID-0016R Wiring Diagrams
Shows input and output connection points for UID-0808R and UID-0016R modules.
UID-0808T and UID-0016T Wiring Diagrams
Shows input and output connection points for UID-0808T and UID-0016T modules.
UID-1600 and UID-0808THS Wiring Diagrams
Shows input and output connection points for UID-1600 and UID-0808THS modules.
Detailed Input Wiring Specifications
General Input Wiring Guidelines
Covers earthing, wire sizing, and signal routing for optimal input wiring.
Input Wiring for UID-0808R, UID-0808T, UID-1600
Details input arrangements and sink/source wiring for specific models.
Input Wiring for UID-0808THS
Explains input groups, sink/source wiring, and high-speed input configurations for UID-0808THS.
High Speed Inputs and Output Wiring Details
High Speed Input Modes and Configurations
Describes input modes (Quadrature, Pulse/Direction) and high-speed input configurations.
Wiring Relay Outputs (UID-0808R, UID-0016R)
Details power supply requirements and connection for relay outputs on specific models.
Output Wiring Specifications and Lifespan
Relay Output Wiring (UID-0808R, UID-0016R)
Explains the arrangement and wiring for relay outputs on UID-0808R and UID-0016R.
Increasing Relay Contact Life Span
Provides methods to extend relay contact lifespan using diodes or RC snubbers.
Transistor Output Wiring (UID-0808T, UID-0016T)
Details power supply and connection for transistor outputs on specific models.
UID-0808THS Output Power Supply
Covers the external 24VDC power supply requirement for UID-0808THS outputs.
Advanced Output Configurations and PWM
Output Protection and Digital/PWM Configuration
Describes short-circuit protection and configuration options for digital and PWM outputs.
High Speed PWM Output Wiring
Details wiring for high-speed PWM outputs, including cable type and common connection.
Technical Specifications - Inputs
General Module Input and Output Specifications
Lists general specs like part numbers, input/output types, and isolation for modules.
Input Specifications for UID-1600
Provides detailed input specifications including type, isolation groups, and voltage for UID-1600.
Input Specifications for UID-0808R, UID-0808T
Provides detailed input specifications for UID-0808R and UID-0808T modules.
Technical Specifications - UID-0808THS Inputs
UID-0808THS Input Specifications
Details input configuration, high-speed inputs, frequency, and pulse width for UID-0808THS.
High Speed Input Modes Explained
Illustrates Quadrature and Pulse/Direction modes for high-speed inputs with timing diagrams.
Technical Specifications - Outputs
Output Specs for UID-0808R, UID-0016R
Lists output type, isolation, current, voltage, and switching times for UID-0808R/UID-0016R.
Output Specs for UID-0808T, UID-0016T
Lists output type, isolation, current, voltage, and switching times for UID-0808T/UID-0016T.
Output Power Supply and Bus Consumption
Details voltage, current consumption, and bus current for module outputs.
Technical Specifications - UID-0808THS Outputs
UID-0808THS Output Specifications
Details output type, voltage drop, leakage, switching times, and PWM frequency for UID-0808THS.
UID-0808THS PWM Cable Requirements
Specifies cable types for different PWM output channels on UID-0808THS.
Module Status Indicators and Environmental Data
LED Status Indications
Explains the meaning of different LED colors and states for module operational status.
Environmental Operating Conditions
Lists protection rating, operating/storage temperatures, humidity, altitude, shock, and vibration.
Module Physical Dimensions and Weight
Module Weight Specifications
Provides the weight for each Uni-I/O module model in kilograms and pounds.
Module Physical Dimensions Diagrams
Shows diagrams with side, top, and front views and dimensions for all module models.
Important Notes and Document Disclaimers
Notes on Relay Contact Life Expectancy
Notes that relay contact lifespan depends on application and load types.
Notes on UID-0808THS High Speed Blocks
Explains the dual-use of high-speed blocks for inputs or outputs on UID-0808THS.
Document Information and Legal Notices
Contains disclaimers regarding product information, warranties, and trademarks.