Canon Vb-C60 - Ptz Network Camera Start Manual page 42

Network camera vb-c60 start guide
Hide thumbs Also See for Vb-C60 - Ptz Network Camera:
Table of Contents

Advertisement

Step2 Connection to the Network
External power supply
When using external power supply, use the Power
Connector (→ P.vii) supplied with the camera as shown
on the right.
Supply 12VDC or 24VAC from a power supply
insulated from 100-240VAC supply. You can connect
12VDC power supply without regard to the polarity.
When using an external power supply, make sure that
the voltage falls within the ranges below.
AC24V: Voltage fluctuation within AC24V±10%
(within 50Hz or 60Hz±0.5Hz)
Current supply capability over 1.0A per camera
DC12V: Voltage fluctuation within DC12V±10%
Current supply capability over 1.5A per camera
* If using a DC12V battery power source, make sure to use the DC12V by connecting a resistor
that is between 0.5 and 1.0Ω, and over 20W in series to the power supply line.
Recommended power supply cables [reference]
Cable (AWG)
Conductor diameter
(ømm)
12VDC
Max. cable length (m)
Max. cable length (ft)
24VAC
Max. cable length (m)
Max. cable length (ft)
Use a UL cable (equivalent to UL-1015) for 12VDC or 24VAC.
● The camera head position is automatically initialized when the power is turned ON.
● Do not touch the camera head while its position is being initialized, or the
Note
head position may not be initialized correctly, or other malfunctions may occur.
● After turning off the camera, please wait at least 5 seconds before turning it on
again. Turning the power back on within less than 5 seconds may cause a
malfunction. When connecting and disconnecting the power, always observe the
precautions given in "a Safety Precautions - Notes on PoE HUB" (→ P.xv).
● Read the manual of the PoE HUB for how to power it ON or OFF.
● You can connect an AC adapter (option) to a camera while it is powered using a
PoE HUB. In this case, power is supplied using PoE, and the AC adapter is not
used. When the PoE-supplied power is disconnected, the power supply automatically
switches to the AC adapter.
2-8
#24
#22
(0.52mm)
(0.65mm)
(0.020inch)
(0.026inch)
5
9
16.4
29.5
11
18
36.1
59.0
The network connection is now complete.
Screwdriver
Tightening torque:
0.2 N·m (max.)
Stripping length
approx. 4mm - 6mm
(0.16inch - 0.24inch)
Power
Connector
(Supplied)
#20
#18
(0.82mm)
(1.03mm)
(0.032inch)
(0.041inch)
14
23
45.9
75.4
29
46
95.1
151.0
#16
(1.30mm)
(0.051inch)
32
105.0
64
210.0

Advertisement

Table of Contents
loading

Table of Contents