DESCRIPTION OPERATION - DD-3 ACTUATOR (FIG. 1) - ™ NORMAL RUNNING The DD-3 ™ and SD-3 ™ are air operated actuators with a For normal operation full reservoir pressure is applied mechanical push shaft lock. The DD-3 actuator (see Fig. ™...
Various control systems are used to achieve the proper REMOVING DD-3 ACTUATOR ™ sequence of control signals. Bendix brochure “Off Highway Vehicle Braking System” (BW 1283) explains one such With the actuators in a released position, disconnect the system. air lines to the service and auxiliary ports. Move the park...
5. Spread clamping rings slightly, just enough to slip rings collar bores in the non- pressure plate. The air passage off plates, It may be necessary to use a soft mallet to from the lock port to piston bore should be checked for break the clamping rings loose.
Page 5
OPERATING - DD-3 ACTUATOR ™ to the nearest Bendix authorized distributor for a factory With the actuator in the released position, make several reconditioned actuator under the repair exchange plan. If brake applications and note that actuators apply and release this is not possible, the actuator can be repaired with genuine properly.