Element4 Summum 70 3/S Installation, Operation And Owner's Manual

Direct vent gas fireplaces

Advertisement

Quick Links

Summum 70 F
Product Info
Summum 100 F
Product Info
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed for the
protection of children and other at-risk individuals.
Une barrière conçu pour réduire le risque de brûlure par le verre de visualisation chaude est fournie avec cet appareil et doit être
installé pour la protection des enfants et autres personnes à risque.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could
result in serious injury, death, or property damage.
- Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not
use any phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call
the fire department.
- Installation and service must be performed
by a qualified installer, service agency or the
gas supplier.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
Element4 Gas Fireplaces Rev #05102022
Summum 70 C
Summum 70 3S
Product Info
Product Info
Summum 100 3S
Summum 100 C
Product Info
Product Info
4006611
Installation, Operation and
Owner's Manual
Summum 70 F
Summum 70 C
Summum 70 3/S
Summum 100 F
Summum 100 C
Summum 100 3/S
Direct Vent
Gas Fireplaces
Une surface vitrée chaude
peut causer des brûlures.
Laisser refroidir la surface
vitrée avant d'y toucher.
Ne permettez jamais á un enfant
de toucher la surface vitrée.
AVERTISSEMENT:
INCENDIE OU D'EXPLOSION
Le non-respect des avertissements de sécurité à la lettre
pourrait entraîner de graves blessures , la mort ou des
dommages matériels.
- Ne pas entreposer ni utilizer d'essence ni d'autres vapeurs
ou liquides inflammables dans le voisinage de cet appareil
ou de tout autre appareil.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ
• Ne pas tenter d'allumer d'appareil.
• Ne touchez á aucan interrupteur. Ne pas vous servir des
téléphones se trouvant dans le bátiment ou vous trouvez.
• Quitter immédiatement le bâtiment.
• Appelez immédiatment votre fournisseur de gaz depuis
un voisin. Suivez les instructions du fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz
appelez le service des incindies.
- Installation et l'entretien doivent être effectués par un installa-
teur qualifié, une agence de service ou le fournisseur de gaz.
INSTALLATEUR: Laissez cette notice avec l'appareil.
CONSOMMATEUR: Conservez cette notice pour
consultation ultérieure.
1
May 2022
EuropeanHome.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Summum 70 3/S and is the answer not in the manual?

Questions and answers

Summarization of Contents

Important Safety Information
Caution: Hot Surfaces and Children
Warns about extremely hot surfaces and the need for supervision of children and pets.
General Safety Warnings and Precautions
Consolidates critical safety advisories including installation, grounding, gas, and handling.
Installation and Service Safety Guidelines
Emphasizes qualified personnel for installation, service, and avoiding product modifications.
Key Installation Points
Essential Installation Checklist
Covers crucial installation requirements like records, electrical, media, framing, and gas pressures.
Planning Your Gas Fireplace
Convection Airflow and Overall Design
Explains the convective airflow system and design considerations for air outlets.
Venting and Gas Supply Considerations
Details critical questions about venting effectiveness and gas pipe routing for installation.
User Information
Fireplace Operation: How It Works
Describes the convective airflow system, illustrating warm air movement and room air intake.
Specifications and Dimensions
Appliance Ratings and AC Adapter Specs
Provides detailed technical ratings, gas pressures, and AC adapter specifications for models.
Summum 70 F Specifications
Dimensions for Summum 70 F
Presents a dimensional diagram and table for the Summum 70 F model.
Summum 70 CL Specifications
Dimensions for Summum 70 CL
Presents a dimensional diagram and table for the Summum 70 CL model.
Summum 70 3/S Specifications
Dimensions for Summum 70 3/S
Presents a dimensional diagram and table for the Summum 70 3/S model.
Summum 100 F Specifications
Dimensions for Summum 100 F
Presents a dimensional diagram and table for the Summum 100 F model.
Summum 100 CR Specifications
Dimensions for Summum 100 CR
Presents a dimensional diagram and table for the Summum 100 CR model.
Summum 100 3/S Specifications
Dimensions for Summum 100 3/S
Presents a dimensional diagram and table for the Summum 100 3/S model.
Fireplace Parts Identification
Component Breakdown and Description
Identifies and describes the various parts of the fireplace, including the vent collar.
Clearances
Locating and Placing the Fireplace
Details considerations for selecting a location and placing the appliance safely.
Clearances to Combustible Materials
Specifies minimum distances required between the fireplace and combustible surfaces.
Clearances to Non-Combustible Materials
Outlines minimum distances to non-combustible surfaces and material restrictions.
Mantel Installation Clearances
Provides guidelines for safe installation of mantels in relation to the fireplace opening.
Typical Clearance Diagrams
Illustrates standard clearance requirements for air openings and room ceiling.
Gas and Electric Requirements
Gas Line Installation Procedures
Details the proper procedures and codes for installing the gas supply line.
Electrical Requirements and Grounding
Covers necessary electrical connections, including receptacle and grounding standards.
Venting
Venting Configuration and Components
Explains the direct vent system, approved components, and basic configuration rules.
Calculating Vent Sections and Elbows
Guides on calculating total vertical and horizontal sections and understanding vent pipe types.
Installing a Vent Restrictor
Details the use and installation of a restrictor plate for proper venting performance.
Vertical Termination Clearances
Specifies required clearances for vertical vent terminations above roofs and walls.
Horizontal Vent Termination Clearances
Lists required clearances for horizontal vent terminations relative to windows and walls.
Enclosing the Fireplace
Material Selection for Enclosure
Defines and lists approved combustible and non-combustible materials for enclosing the fireplace.
Enclosure Framing and Clearance Reduction
Covers framing requirements and methods for reducing clearances to combustible walls.
Minimum Enclosure Area Requirements
Specifies minimum clear dimensions for enclosing the Summum 70 F fireplace.
Locating and Mounting Controls
Details placement of controls, wall access doors, and cold climate insulation.
Test Fire Procedure
Outlines the step-by-step process for test firing the fireplace to ensure proper operation.
Installing the Fire Media
Fire Media Arrangement and Installation
Guides on arranging and installing logs, glass, and chips for optimal flame appearance.
Operating LED Lighting
Explains how to control the brightness and pulsing of the fireplace's LED lighting.
Screen Installation
Screen Installation Steps and Diagrams
Provides instructions and diagrams for installing the fireplace screen, including tabs and magnets.
Operating the Fireplace
Pre-Operation Checks and Remote Pairing
Covers essential pre-fire checks, gas valve operation, and remote/receiver synchronization.
Remote Control Functions and Settings
Explains operation of the 10-button remote, including time, temperature, and modes.
Flame Height and Mode Adjustments
Details how to adjust flame height, use standby mode, and turn the fireplace off.
Understanding Operating Modes
Describes Thermostatic, Program, and Eco modes for fireplace operation and temperature control.
Advanced Operating Features
Covers auxiliary features like automatic shut-off, timer functions, and LED modes.
First Fire Burn-off Procedure
Guides on the initial heating process, addressing odors and condensation.
Maintenance
Removing and Cleaning Glass Panels
Provides step-by-step instructions for safely removing, cleaning, and reinstalling glass panels.
Burner and Pilot Maintenance
Details visual checks for burner flames, pilot presence, and cleanliness.
Thermocouple and Vent Maintenance
Covers checks for thermocouples and inspection of the venting system for optimal performance.
Replacement Parts List
Lists available replacement parts with corresponding part numbers for the fireplace system.
Warranty Information
Product Installation Record
A form for installers and customers to record essential fireplace installation details.
Appendix One: Massachusetts Certification
Massachusetts Installation Requirements
Outlines specific regulations for installing gas appliances in Massachusetts, including CO detectors.
Appendix Two: Troubleshooting
Troubleshooting Flow Chart
Provides a systematic guide to diagnose and resolve common operational issues with the fireplace.
Appendix Three: Smart Home Connection
Connecting to a Smart Home System
Details how to connect the fireplace to external automation systems using a smart home cable.
Appendix Four: Optional Panels
Installing Optional Glass Panels
Instructions for installing optional decorative glass panels on the fireplace.
Appendix Five: Procontrol App Errors
Error Codes and Troubleshooting for Procontrol App
Lists error codes from the app and their possible causes and solutions.

Table of Contents