IFM Electronic Efector 500 PN2024 Operating Instructions Manual

IFM Electronic Efector 500 PN2024 Operating Instructions Manual

Combined pressure sensor

Advertisement

Operating instructions
Combined pressure sensor
UK
PN20xx

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Efector 500 PN2024 and is the answer not in the manual?

Questions and answers

Summarization of Contents

Preliminary Note
Symbols Used
Explains symbols used in the manual for clarity and understanding.
Function
Communication, Parameter Setting and Evaluation
Details how the unit communicates, allows parameter adjustment, and evaluates process data.
Switching Function
Describes how output signals change based on set pressure limits and selected functions.
Analogue Function
Explains the configuration for analogue output signals (4-20mA or 0-10V) based on pressure.
Menu
Menu Structure
Visual representation of the device's menu hierarchy and parameter flow.
Explanation of the Menu
Provides detailed descriptions for each parameter and menu item found in the device.
Parameter Setting
Parameter Setting General
Outlines the general three-step procedure for selecting and adjusting any parameter.
Locking / Unlocking
Describes the procedure to electronically lock or unlock the device settings to prevent accidental changes.
Setting the Output Signal
Covers setting output functions, switching limits, and scaling analogue values for output signals.
User Settings (optional)
Allows customization of units, display, zero-point calibration, and timing for switching outputs.
Setting the Output Polarity
Defines the output polarity (pnp or npn) for the switching outputs.
Setting the Damping for the Switching Outputs
Adjusts the response time for switching outputs to filter rapid pressure fluctuations.
Setting the Damping for the Analogue Output
Configures the response time for the analogue output to smooth out signal variations.
Service Functions
Accesses service functions like reading min/max pressure values and clearing memory.
Reading the Min./Max. Values for the System Pressure
Allows viewing and clearing the stored minimum and maximum system pressure values.
Operation
Read the Set Parameter Values
Explains how to briefly view configured parameter values while in operating mode.
Fault Indication
Lists and describes the error codes displayed by the unit for troubleshooting.
Technical Data
Setting Ranges
Provides detailed tables of minimum and maximum setting ranges for various pressure units and sensor models.

Table of Contents