Wiring other instruments
MCU600
Clutch relay out: 8
NMEA2 - in/out: 7
NMEA1 - in: 6
NMEA common: 5
NavBus -, Blue: 4
NavBus +, Orange: 3
Ground, Black: 2
12 V power +, Red: 1
Note:
Refer to the instrument's installation manual for more wiring information.
If adding more than three display units or other series instruments, fit a separate light-duty power supply
for the extra instruments (see section 3-4 or the instrument's installation manual)
The external alarm outputs (green wire) of Northstar series instruments and 500 series chartplotters
can be connected together to drive the external beepers and lights.
In systems with several other instruments, we recommend using NavBus junction boxes to simplify
wiring (see the NavBus Installation and Operation Manual).
Follow the wiring guide (see section 3-2-2).
26
Addtional AP380
display units
Display
units
Green
(from one display unit only)
Northstar Explorer AP380 System Installation and Operation Manual
Other series
A GPS, such as a
instruments
Northstar Explorer
Units
GPS
NMEA
in & out
Green
Green
567
Power,
NMEA in
Clutch, optional
(see section 3-4-2)
NMEA in/out
GPS NMEA out
GPS NMEA common
Light duty power
(see section 3-4-1)
Beepers and lights
(see previous page)