1
Find a suitable location for the unit as described above.
2
Mount the unit with the three screws provided. Use a level to ensure the unit is vertical to within 10°.
3
Wire the cable back to the MCU600, following the wiring guide (see section 3-2-2).
Note
If you move the gyro with respect to the compass while the power is on, wait for the heading to
stabilise.

3-8 Installing the Explorer AP380 display unit and other instruments

There are two mounting arrangements:
Flush mounting requires a solid panel with
access behind for wiring and mounting screws.
After flush mounting, the display cannot be
tilted or moved after installation to reduce any
unwanted glare or reflections. Carefully select
the best viewing position before installation. This
would generally be in a shaded area.
Less than
10° 10°
Northstar Explorer AP380 System Installation and Operation Manual
Holes in the bulkheads must
be at least 18.5 mm (0.73")
diameter.
Plug connector into the Gyro socket
Flush mounting directions
1
Cut a hole in the bulkhead for the display unit
using the flush mount template as a guide.
2
Drill four holes for the mounting studs using
the flush mount template as a guide.
3
Screw the four studs into the brass inserts in
the back of the display unit.
4
Sit the display unit in place and fit the
washers and nuts to the studs.